BUCK STEEL, INC.
6810 LYONS TECH. CIR 4105
COCONUT CREEK, FL 33073
DATE: 10/10/12
PORT OF PALM BEACH FCL CARGO TRANSFER FACILITY
JOB NO. 2345
BUILDING SIZE:
WIDTH : 40 ft.
LENGTH : 60 ft.
EAVE HT : 16 ft.
JOBSITE : RIVIERA BEACH, FL (EXPORT)
To Whom It May Concern:
This is to certify that the above referenced building components
furnished by Metal Building Manufacturer are designed with good engineering
practice and in accordance with the order documentation and the applicable
structural design provisions set forth in the applicable MBMA "Low Rise
Building Systems Manual", the applicable AISCO5 and NAUS07 Manuals, and the
applicable IBC code, to sustain the requested design loads, specifically
as follows:
The criteria for application of design loads are follows
Governing Code : FBC 10 (IBC 12)
Roof Dead Load 2.000 psf plus wt. of metal bldg structure
Roof Live Load 20.00 psf
Frame Live Load 20.00 psf
Collateral Load 0.5 psf
Wind Load (3 sec gust) : 180 mph
Enclosure Type CLOSED
Wind Exp. Cat C
Wind Imp. Factor 1.00
This certification is limited to the structural design of the frames,
secondary, and roof/wall covering manufactured or supplied by
Metal Building Manufacturer. Accessory items such as doors, windows,
louvers, translucent panels, and ventilators supplied by the customer
are not included. This certification specifically excludes any foundation,
masonry, or general contract work.
Sincerely,
Richard T. Smith
PENN
VflhOSMISM212
LIPAAGEgisPh:()06)8884174
lllllllllllllll
\c py..
p lllll
• •
. N 43547 ii e ser .
RICHARD T. SMITH, P.E. *
*77
STATE OF 4J:
•0 •
I'Ci. ,? s
,
'1061e6/0N.A.C• %%%%
tttttttttttttttt
REVIEWED
By Richard 7' Saddl at 1:32 pa Oct 11, 2012
EFTA_R1_00317442