CAMP M.gnismil op' Due List 737-73QB3 S/N 29102 (YG001) N834BZ
OWNER: FIRST VIRTUAL AIR LLC. OPERATOR: FIRST VIRTUAL AIR LLC.
ADDRESS: C/O MILLION AIR, LLC ADDRESS: C/O MILLION AIR, LLC
MEDFORD OR 97504 MEDFORD OR 97504
PHONE: 541-245-2888 PHONE: 541-245-2888
FAX: 541-245-0205 FAX: 541-245-0205
ANALYST: ANTHONY AMBROSINO 877-411-CAMP (2267) (OFFICE) 800-787-9749
(EFAX-CARDS)
EMAIL: 631-588-3200 (OFFICE) 631-980-4222 (FAX)
PROJECTED : 48 MOS. to 04-AUG-2021
AIRCRAFT SERIAL/REGNO: 29102 (YG001)/N834BZ MODEL: 737-73QBJ MANUFACTURER: BOEING COMPANY
DATES LAST ACTUALS PROJECTED
INSERVICE DATE: 30-JUN-2000 8439 NC HRS as of 01-AUG-2017 9039
3428 AFL as of 01-AUG-2017 3728
7586 APH as of 01-AUG-2017 8186
APU SERIAL/PART: P-5012/3800702-1 MODEL: 131-95 MANUFACTURER: HONEYWELL
INSTALLED ON 30-JUN-2000 LAST ACTUALS PROJECTED
69 APU HRS 7586 APU HRS as of 01-AUG-2017 8186
0 APUS 6355 APUS as of 01-AUG-2017 6655
ENGINE NO. 1 SERIAL/PART: 874330/CFM56-7827/53 MODEL: CFM56-7827/B3 MANUFACTURER: CFM INTERNATIONAL S.A.
INSTALLED ON 30-JUN-2000 LAST ACTUALS PROJECTED
116 ENG. HRS 163 NC HRS 8439 ENG. HRS as of 01-AUG-2017 9039
116 ENC 3428 ENC as of 01-AUG-2017 3728
ENGINE NO. 2 SERIAL/PART: 875332/CFM56-7627/53 MODEL: CFM56-7827/B3 MANUFACTURER: CFM INTERNATIONAL S.A.
INSTALLED ON 30-JUN-2000 LAST ACTUALS PROJECTED
116 ENG. HRS 163 NC HRS 8439 ENG. HRS as of 01-AUG-2017 9039
116 ENC 3428 ENC as of 01-AUG-2017 3728
BOEING NO 61:0 PRE TRAOEMAAJG OF THE BOEING COMPANY
04-AUG-2017 © CAMP SYSTEMS 1 Of 42
EFTA00597210
CAMP NEW REQUIREMENT/FLAGGED ITEMS
Atigtheafrem Mertnihir
Operator Review And Action Required
737-73QB3 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
These tasks or requirements have been added newly to your aircraft status. Please review them and approve or modify as appropriate. Please
pay particular attention to the Base and Next Due Times for these tasks. his important to note that any task that has insufficient Information
(marked by 2), will never come due unless the necessary Information Is provided by you.
TASK NO TASK DESCRIPTION EFFECTIVE DATE UNIT INTERVAL BASE TIME NEXT DUE DISPOSITION
Current Change To
FAA 2017-14-13 EQUIPMENT/FURNISHINGS - FLIGHT COMPARTMENT - CAPTAIN'S AND FIRST OFFICER'S RUDDER PEDAL HEEL REST COVER ASSEMBLY FASTENER
TORQUE CHECK AND REPLACEMENT OF THE AFFECTED SCREW AND ASSOCIATED NUTPLATE
23-AUG-2017 DUE NEXT MOS 21 23-AUG-2017 231,!AY•2C 7 9 b NDATCRY
HRSIMSC
REF: AD AFL
NEW REQUIREMENT ADDED ON 20.RJL•2017. REVIEW BASE TIMES TO ENSURE CORRECT DUE MMES.
AUTHORIZED BY CERT.a DATE
7-Insufficient Information (s) Suppressed Requirement •-Estimated Due (New Requirement) (EBT}£etlmated Base Time
04-AUG-2017 C CAMP SYSTEMS
2 Of 42
EFTA00597211
qmp
A,,iatiostfrum thvgriramd up'
Due List
737-73Q83 S/N 29102 (YG001) (N8348Z): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ENG A' C
TIME REMAINING
25-300-00 (0061) RESTORE AFT LM DINNING ROOM LIFE RAFT RESTORE
PIN: 64404-10112 MOS 36 ZS-JUL-2010 01-JUL-2017 OVD
HRSi'MSC
S:N: 0032
AFL
REF: BTC 25-300-O0.01
WO: 144 MOS INSP (2/2012)
ASB 737-29A1119 R1 HYDRAULIC POWER - HYDRAULIC SYSTEMS A AND B - WIRE BUNDLES AND HYDRAULIC TUBE CLAMP RECOMMENDED
INSTALLATION, ALERT SERVICE BULLETIN
MOS 24 (EFF) 04-AUG-2017 0d 04-AUG-2017
HRSilISC
AFL
REF: BULLETINS
+ 29-230-00 OPERATIONAL CHECK STANDBY RUDDER SYSTEM TO INCLUDE OBSERVING LOW PRESSURE LIGHT ILLUMINATION
AND THEN EXTINGUISHING.
29.480 DAYS t50 23-MAR-2017 20-AUG-2017 16d 20-AUG-2017
HRSIMSC t000 841910 9419.20 980.2
AFL 3419
REF: BTC 29-230-00.01
WO: 144 MOS INSP (2/2012)
050150 1 MONTH INSPECTION
MOS 1 28-JUL-2017 28-AUG-2017 24d 28-AUG-2017
HRSiliSC 8439
AFL 3428
REF:
FAA 2016-18-01 PARA LUBRICATE THE FORWARD AND AFT TRUNNION PIN ASSEMBLIES OF THE LEFT AND RIGHT MLG AND REPEAT MANDATORY
(G)
DAYS 30 01-AUG-2017 31-AUG-2017 27d 31-AUG-2017
HRSiliSC 8439
AFL 3428
REF: AD
+ 050010 6 MONTH INSPECTION
MOS 6 23-MAR-2017 23-SEP-2017 50d 23-SEP-2017
HRSAISC 8419.20
AFL 3419
REF:
(xEXT)- Extension Incorporated in the next due (s)- Suppressed Requirement + - FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
• - Estimated Due (applies to New Requirement) H - Task also due In hours due list
CAMP SYSTEMS
3 Of 42
EFTA00597212
qmp Aviaries. frum up'
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ENG A' C
TIME REMAINING
H 285001 TEST EXTRACTED DETECTION SAMPLE FOR MICROBIAL GROWTH
MOS 6 23-MAR-2017 23-SEP-2017 50d 23-SEP-2017
HRSA1SC 400 841910 8819.20 380.2
AFL 3419
REF:
WO: 144 MOS INSP (2/2012)
53 00-20 DETAILED INTERNAL INSPECTION OF UPPER EXOGRID TIE ROD-TO-STRINGER ATTACHMENT AT STRINGERS 4L AND
4R PER 53-10-15.601
MOS 18 30-MAR-2012 30-SEP-2017 M 57d 30-SEP-2017
HRSMSC 5059
AFL 1943
REF:
WO: 144 MOS INSP (2/2012)
+ 34-BBJ-01 SERVICE HEADS UP DISPLAY OVERHEAD UNIT DESICCANT CAPSULE
34.452 MOS 3 05-JUL-2017 05-OCT-2017 62d 05-OCT-2017
HRSi MSC 8438.40
AFL 3426
REF: BTC 34.88)-01-O1
WO 144 MOS INSP (2/2012)
+ 34-21.00 PERFORM RVSM HEIGHT MEASUREMENT VERIFICATION FROM AGHME RVSM
MOS 12 11-NOV-2016 11-NOV-2017 99d 11-NOV-2017
HRS/MSC 1000 8417.40 9417.40 978.4
AFL 3418
REF:
25420-02 MEDAIRE AFAK MEDICAL KIT
Pm: 500097 MOS 12 TSO:0 06-DEC-2016 06-DEC-2017 124d 06-DEC-2017
HRS/MSC TSO:0 8419.20
SN: 120116002
AFL TSO:0 3419
REF:
26-210-00 (002.1) REPLACE APU FIRE EXTINGUISHER BOTTLE AFT SQUIB LIFE LIMIT
26.290 RN: 30903872-1 MOS 120 12-DEC-2007 12-DEC-2017 130d 12-DEC-2017
HRS/MSC
SN: 00426
AFL
REF: BTC 26-210-O0.01
(xEXT) • Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set MEM - Estimated Base Time (EFF) - Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
4 Of 42
EFTA00597213
qmpAviaries. frum thvgriramd up*
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ENG A' C
TIME REMAINING
28-054-00 OPERATIONAL CHECK (BITE) THE FUEL PUMP GFI RELAY
28.890 MOS 12 10-JAN-2017 10-JAN-2018 159d 10-JAN-2018
HRSilISC
AFL
REF: BTC 28.054-00.01
WO: 144 MOS INSP (212012)
28456-00 FUNCTIONALLY CHECK THE CENTER TANK FUEL BOOST PUMP POWER FAILED ON PROTECTION SYSTEM
28.895 MOS 12 10-JAN-2017 10-JAN-2018 159d 10-JAN-2018
HIRSiliSC
AFL
REF: BTC 28.056-00.01
28-AWL-20 REVIEW OVER-CURRENT AND ARCING PROTECTION ELECTRICAL DESIGN FEATURES OPERATION - BOOST PUMP ALI
GROUND FAULT INTERRUPTER (GFI)
28.900 MOS 12 10-JAN-2017 10-JAN-2018 159d 10-JAN-2018
HRS MSC 8419.20
AFL 3419
REF: See Workcard
WO: 144 MOS INSP (212012)
28-AWL-23 FUNCTIONALLY TEST CENTER TANK FUEL BOOST PUMP POWER FAILED ON PROTECTION SYSTEM. ALI
28.320 MOS 12 10-JAN-2017 10-JAN-2018 159d 10-JAN-2018
HRS'MSC 8419.20
AFL 3419
REF: See Wcrkcard
24-120-00 (001.1) RESTORE MAIN BATTERY RESTORE
24.240 PM: 539CH-1 MOS 12 20-JAN-2017 20-JAN-2018 169d 20-JAN-2018
S/N: 0905200128A56
AFL
REF: BTC 24-120-00-01
WO: 144 MOS INSP (2/2012)
24-12040 (002.1) RESTORE AUXILIARY BATTERY RESTORE
24.240 PM: 024147-000 MOS 12 20-JAN-2017 20-JAN-2018 169d 20-JAN-2018
SM: 090520004E0ED
AFL
REF: BTC 24-120-00-01
WO: 144 MOS INSP (2/2012)
(xEXT) • Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
5 Of 42
EFTA00597214
qmpAviaries. frum thvgriramd up*
Due List
737-73Q83 S/N 29102 (YGOO1) (N83482): 8439 HRS, 3428 AFL as of O1-Aug-2O17
Calendar Section
Projected To: 48 MOS. to O4-AUG-2O21
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
FNC.:
TIME REMAINING
28.199-00 FUNCTIONALLY CHECK (RESISTANCE MEASUREMENT) THE BONDING BETWEEN MOTOR OPERATED VALVE
ACTUATOR AND THE ADJOINING STRUCTURE.
MOS 72 30-JAN-2012 30-JAN-2018 179d 30-JAN-2018
HRS MSC
AFL
REF: 8TC 28-199-00-01
28-AWL-24 REVIEW SPAR VALVE MOV ACTUATOR - LIGHTNING AND FAULT CURRENT PROTECTION ELECTRICAL BOND ALI
28.905 MOS 72 30-JAN-2012 30-JAN-2018 179d 30-JAN-2018
HRSilISC
AFL
REF: See Workcard
35.12.85 (3) NO.1 OBSERVER OXYGEN MASK
35.020 PA: MC10-08-109 MOS 12-JUN-2014 31-JAN-2018 M 180d 31-JAN-2018
HRSAISC O:C 6582.60
SE5875I
AFL 2568
REF:
FAA 2005-18-23 CORROSION PROTECTION OF THE ELECTRICAL CONNECTORS IN THE MAIN WHEEL WELL MANDATORY
MOS 24 26-FEB-2016 26-FEB-2018 206d 26-FEB-2018
HRS MSC 7907.40
AFL 3156
REF: AD
WO 144 MOS INSP (2/2012)
ASB 737-24A1148 R1 CORROSION PROTECTION OF THE ELECTRICAL CONNECTORS IN THE MAIN WHEEL WELL, ALERT SERVICE
BULLETIN
MOS 12(s) 26-FEB-2016 26-FEB-2018 M 206d 26-FEB-2018
HRS/MSC 7907.40
AFL 3156
REF: BULLETINS
WO 144 MOS INSP (2/2012)
FAA 2006-21-01 PARA REPETITIVE LUBRICATION OF THE AILERON BALANCE TAB COMPONENTS MANDATORY
(I)
MOS 12 23-MAR-2017 23-MAR-2018 2310 23-MAR-2018
HRS'MSC 4000 841020 12419.20 3980.2
AFL 3419
REF:
(xEXT) - Extension incorporated in the next due Is) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
6 Of 42
EFTA00597215
qmpAviaries. frum thvgriramd up'
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
CENG ) A/C TIME REMAINING
FAA 2011-27-03 PARA LUBRICATE TO PREVENT AN UNDETECTED FAILURE OF THE PRIMARY LOAD PATH FOR THE BALLSCREW IN THE MANDATORY
(G)(1)(1)(2) DRIVE MECHANISM OF THE HSTA AND SUBSEQUENT WEAR AND FAILURE OF THE SECONDARY LOAD PATH IN
ACCORDANCE SERVICE BULLETIN 737-27A1277 R2
MOS 12 23-MAR-2017 23-MAR-2018 231d 23-MAR-2018
HRS4.1SC 1600 8419.20 10019.20 1580.2
AFL 3419
REF: AD
+ 050020 12 MONTH INSPECTION
MOS 12 23-MAR-2017 23-MAR-2018 231d 23-MAR-2018
HRS MSC 8419.20
AFL 3419
REF:
+ 26-450-00 (001.1) DETAILED INSPECTION OF THE PORTABLE HALON FIRE EXTINGUISHER FOR PROPER PRESSURE (IF GAUGE
INSTALLED), WEIGHT, AND CONDITION
MOS t2 23-MAR-2017 23-MAR-2018 231d 23-MAR-2018
HFtS/MSC 8419.20
AFL 3419
REF: BTC 26-450-00.01
28-115-00 FUNCTIONALLY CHECK THE CENTER TANK BOOST PUMP AUTO SHUTOFF SYSTEM
28.115 MOS 12 23-MAR-2017 23-MAR-2018 231d 23-MAR-2018
HRS%ISC
AFL
REF: BTC 28-115-00-01
+ 050030 24 MONTH INSPECTION
MOS 24 26-MAR-2016 26-MAR-2018 234d 26-MAR-2018
HRSiMSC 7964.90
AFL 3184
REF:
+ 23-060-00 OPERATIONAL CHECK OF THE ULB
23.090 MOS 24 26-MAR-2016 26-MAR-2018 234d 26-MAR-2018
HRSIASC 7963.40
AFL 3184
REF: BTC 23-060-00-01
WO: 144 MOS INSP (2/2012)
(xEXT) - Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
7 Of 42
EFTA00597216
qmp AL,iariost frum /Arvin/old .4'
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
FNC. : A' C
TIME REMAINING
+ 050050 72 MONTH INSPECTION
MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSMSC 5059
AFL 1943
REF:
• 20-02040 GENERAL VISUAL INSPECTION OF HIRFIL SENSITIVE WIRE RUNS INSIDE THE PRESSURE
VESSEL. LOOK FOR OBVIOUS DAMAGE AND CONDITION OF SECURITY OF WIRE RUNS
20.030 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSMSC 5059
AFL 1943
REF: SIC 20.020-00.01
WO 144 MOS INSP (2/2012)
+ 20-050-00 DETAILED VISUAL INSPECTION OF HIRFIL SENSITIVE CONNECTORS INSIDE THE PRESSURE VESSEL. DURING THE
INSPECTION DO NOT DISCONNECT CONNECTORS. LOOK FOR CONDITION, SECURITY, AND SIGNS OF CORROSION
20.090 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRS/MSC 5059
AFL 1943
REF: SIC 20-050-00-01
WO 144 MOS INSP (2/2012)
« 20-060-00 FUNCTIONAL CHECK OF HIRFIL. SENSITIVE CONNECTORS INSIDE THE PRESSURE VESSEL BY DC RESISTANCE
CHECK FROM BACKSHELL TO GROUND.
20.100 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSAISC 5059
AFL 1943
REF: SIC 20.060-00.01
WO: 144 MOS INSP (2/2012)
+ 20-070-00 DETAILED VISUAL INSPECTION OF THE HIRFIL SENSITIVE PIG TAILS INSIDE THE PRESSURE VESSEL. LOOK FOR
CONDITION OF SECURITY AND SIGNS OF CORROSION.
20.110 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSMSC 5059
AFL 19.13
REF: BIC 20-070-00-01
WO: 144 MOS INSP (2/2012)
26470-00 (001.1) REPLACE NO. 1 ENGINE FIRE EXTINGUISHER BOTTLE - FORWARD SQUIB LIFE LIMIT
26.040 PiN: M30903871 MOS 120 31-MAR-2008 30-MAR-2018 M 238d 30-MAR-2018
HRSilISC
SM: 465
AFL
REF: BTC 26.070-00.01
(xEXT) - Extension Incorporated in the next due (s) - Suppressed Requirement + - FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
• - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
8 Of 42
EFTA00597217
Due List Calendar Section
CAMP
Avis:km.1ns Ow%mead srp' 737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017 Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
CENCI) A/C TIME REMAINING
26-070-00 (002.1) REPLACE NO. 1 ENGINE FIRE EXTINGUISHER BOTTLE - AFT SQUIB LIFE LIMIT
26.040 PIN: M30903871 MOS 120 31-MAR-2008 30-MAR-2018 238d 30-MAR-2018
HRS/MSC
SM: 467
AFL
REF: 8TC 26-070-00-01
26-070-00 (003.1) REPLACE NO. 2 ENGINE FIRE EXTINGUISHER BOTTLE - FORWARD SQUIB UFE LIMIT
26.041 PIN: M30903871 MOS 120 31-MAR-2008 30-MAR-2018 238d 30-MAR-2018
HRSi'M SC
SA4: 545
AFL
REF: 8TC 26-070-00-01
26-070-00 (004.1) REPLACE NO. 2 ENGINE FIRE EXTINGUISHER BOTTLE - AFT SQUIB UFE LIMIT
26.041 PM: 30903938 MOS 120 31-MAR-2008 30-MAR-2018 238d 30-MAR-2018
HRSi'MSC
S/N: 014
PA
REF: 8TC 26-070-00-01
26-390-00 (01) REPLACE (LDR2) CARGO FIRE EXTINGUISHING SYSTEM FILTER/DRIER
26.035 MOS 72 30-JUN-2000 30-MAR-2018 IA 238d 30-MAR-2018
HRS/MSC 163
AFL 116
REF: 8TC 26-390-00-01
WO: 144 MOS INSP (212012)
26-390-00 (02) REPLACE (LRD1) CARGO FIRE EXTINGUISHING SYSTEM FILTER/DRIER
26.036 MOS 72 30-JUN-2000 30-MAR-2018 IA 238d 30-MAR-2018
HRS/MSC 163
AFL 116
REF: 8TC 26-390-00-01
WO: 144 MOS INSP (212012)
26-390-00 (03) REPLACE (HRD) CARGO FIRE EXTINGUISHING SYSTEM FILTER/DRIER
26.600 MOS 72 30-MAR-2012 30-MAR-2018 IA 238d 30-MAR-2018
HRS'MSC 5059
AFL 1943
REF: 8TC 26-390-00-01
WO: 144 MOS INSP (212012)
(xEXT) - Extension incorporated in the next due (a) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
9 Of 42
EFTA00597218
qmp AL,iariost frum thvgriramd .p*
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
FNC. : A ' C TIME REMAINING
+ 26.40040 (01) FUNCTIONALLY CHECK THE CARGO FIRE EXTINGUISHING TIMER.
26.035 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSilISC 5059
AFL 1943
REF: BIC 26-400-00.02
WO: 144 MOS INSP (2+2012/
+ 26400.00 (02) FUNCTIONALLY CHECK THE CARGO FIRE EXTINGUISHING TIMER.
26.036 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSilISC 5059
AFL 1943
REF: Bit 26-400-00.02
+ 26-400-00 (03) FUNCTIONALLY CHECK THE CARGO FIRE EXTINGUISHING TIMER.
26.600 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSA1SC 5059
AFL 1943
REF: Bit 26-400-00.02
28-10-01 PATS PERFORM CORE VACUUM CHECK OF INDIVIDUAL AUXILIARY FUEL CELLS
MOS 96 30-JUN-2000 30-MAR-2018 M 238d 30-MAR-2018
HRSA1SC 163
AFL 116
REF: See 11.1ori<card
28-10-02 PATS DETAILED INSPECTION AUXILIARY FUEL CELL EXTERIOR STRUCTURE (INCLUDING DOORS/PANELS) FOR DAMAGE
AND CONDITION
MOS 14,1 30-JUN-2000 30-MAR-2018 M 238d 30-MAR-2018
HRSilISC 163
AFL 116
REF: See Worxcard
28-20-06 PATS GENERAL VISUAL INSPECTION OF THE AUXILIARY FUEL SYSTEM CELL INTERNAL HORIZONTAL AND VERTICAL
STRUCTURAL TUBES AND ALL ATTACHMENTS FOR CRACKS AND LOOSE FASTNERS.
MOS 14,1 30-JUN-2000 30-MAR-2018 M 238d 30-MAR-2018
HRSilISC 163
AFL 116
REF: See Worxcard
(xE XI) - Extension incorporated in the next due Is) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
10 Of 42
EFTA00597219
qmp Avie fice• frum /Avg/wend .4'
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
CENG) Arc TIME REMAINING
28-BBJ-01 REMOVE AND INSPECT (DETAILED) THE FOLLOWING ITEMS ON ALL PATS AUXILIARY FUEL
CELLS FOR CONDITION AND SECURITY OF INSTALLATION: FUEL CELLS, FUEL CELL SUPPORT
STRUCTURE, ELECTRICAL CONNECTORS AND CABLES, AND PLUMBING, INTERNAL CELL WALLS,
PLUMBING SUPPORTS. VACUUM TEST EACH CELL PER PATS PS-4.1 PRIOR TO
REINSTALLATION.
28.570 MOS 72 30-MAR-2012 30-MAR-2016 238d 30-MAR-2018
HRS11.1SC 5059
AFL 1943
REF: BIC 28-88J-01-01
WO 144 MOS INSP (2/2012)
286007 DETAILED VISUAL INSPECTION OF THE AUXUILIARY FUEL CELLS FQIS IN TANK WIRE HARNESS, COMPENSATOR
AND SENSOR TUBES FOR SIGNS OF CHAFFING OR RUBBING.
MOS 72 30-MAR-2012 30-MAR-2016 238d 30-MAR-2018
HRSAISC 5059
AFL 1943
REF:
WO: 144 MOS INSP (212012)
33-065-00 REPLACE SELF -LUMINOUS EXIT SIGN LIGHT ASSEMBLY
MOS 72 30-MAR-2012 30-MAR-2016 238d 30-MAR-2018
HRSAISC 5059
AFL 1943
REF:
WO: 144 MOS INSP (2/2012)
38-11-03 WATER FILL OVERFLOW VALVE
38.020 P/N: 1201010 MOS 07-MAR-2014 30-MAR-2018 M 238d 30-MAR-2018
HRS./ASO ac 6295.10
SM: 5112
AFL 2452
REF:
38-240-00 34 GALLON HOT WATER TANK HEATER THERMOSTAT UFE LIMIT
PM: 21542-6-70-1 MOS 36 06-MAY-2015 30-MAR-2016 M 238d 30-MAR-2018
HRS/MSC 7179.60
SIN: N/A
AFL 2857
REF:
APH
WO: 144 MOS INSP (2/2012)
(xE XI) • Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
11 Of 42
EFTA00597220
qmpAviatiostfrum thvgnramd up'
Due List
737-73Q83 S/N 29102 (YGOO1) (N83482): 8439 HRS, 3428 AFL as of O1-Aug-2O17
Calendar Section
Projected To: 48 MOS. to O4-AUG-2O21
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
0401 A I C TIME REMAINING
38.250-00 34 GALLON HOT WATER TANK OVER-TEMPERATURE SWITCH UFE LIMIT
P/N: 4391S14-196 MOS 36 C6-MAY-2015 30-MAR-2018 238d 30-MAR-2018
HRSA1SC 7179.60
AFL 2857
REF:
APH
WO 144 MOS INSP (22012)
38.260-00 34 GALLON HOT WATER TANK SAFETY RELIEF VALVE UFE LIMIT
PIN: FVMX-5C MOS 36 C6-MAY-2015 30-MAR-2018 M 238d 30-MAR-2018
HRSA1SC 7179.60
SN: WA
AFL 2857
REF:
APH
WO: 144 MOS INSP (2/2012)
53-03-01 PATS PERFORM A GENERAL VISUAL INSPECTION OF THE CARGO
BULKHEAD FOR MISSING HARDWARE, SEPARATION, DAMAGE
CRACKING, HOLES OR DISCOLORATION
AND ALL ATTACHMENTS FOR CRACKS AND LOOSE FASTENERS.
MOS 144 30-MAR-2018 Al 238d 30-MAR-2018
HRSI.ISC
AFL
REF: See Worxcard
+ 53-110-00 INSPECT (INTERNAL-GENERAL VISUAL) PASSENGER COMPARTMENT FLOOR STRUCTURE IN WET AREA (WITHIN
APPROXIMATELY 20 INCHES FROM DOORS, GALLEYS
AND LAVS) FROM LOWER LOBE.
53.165 MOS 72 30-MAR-2012 30-MAR-20113 238d 30-MAR-2018
HRSMSC 5059
AFL 1943
REF: BTC 53-110-00-01
WO: 114 MOS INSP (2/2012)
+ 53.150-00 INSPECT (INTERNAL-DETAILED) FORWARD CARGO DOOR CUTOUT SURROUND STRUCTURE
53.185 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRS/MSC 5059
AFL 1943
REF: BIC 53-150-00-01
WO: 144 MOS INSP (2/2012)
(XEXT) - Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
120f 42
EFTA00597221
OM P
Due List Calendar Section
Arialiow f rim the 'ramie( 737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017 Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
I ENO ) MC TIME REMAINING
+ 53-160-00 INSPECT (INTERNAL-GENERAL VISUAL) FORWARD BILGE SKIN PANELS (SKINS, FRAMES, STRINGERS),
LONGITUDINAL LAP SPLICES, AND CARGO DOOR CUTOUT SURROUND STRUCTURE IN BILGE. [NOTE: INSPECTION
INCLUDES THE CIRCUMFERENTIAL SKIN AND STRINGER SPLICE AT STA 500E FOR THE -900ER MODELS]
53.190 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRS11.1SC 5059
AFL 1943
REF: 8TC 53-160-00-01
WO: 144 MOS INSP (212012)
+ 53-240-00 INSPECT (INTERNAL-DETAILED) AFT CARGO DOOR CUTOUT SURROUND STRUCTURE
53.230 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSMSC 5059
AFL 1943
REF: 8TC 53-240-00-01
WO: 144 MOS INSP (212012)
+ 53-250-00 INSPECT (INTERNAL-GENERAL VISUAL) AFT BILGE SKIN PANELS (SKINS, FRAMES, STRINGERS),
LONGITUDINAL LAP SPLICES, CIRCUMFERENTIAL SKIN AND STRINGER SPLICES, [NOTE: LOCATED AT STA 7271 FOR
-900ER AND 727L FOR - 900ER MODELS]; STA 727 BULKHEAD AND PRESSURE WEB, AND CARGO DOOR CUTOUT
SURROUND STRUCTURE IN BILGE.
53.235 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSAISC 5059
AFL 1943
REF: 8TC 53-250-00-01
WO: 144 MOS INSP (212012)
+ 53-260-00 INSPECT (INTERNAL-GENERAL VISUAL) AREA AFT OF CARGO COMPARTMENT INCLUDING: 1. SKIN
PANELS (SKINS, FRAMES, STRINGERS), LONGITUDINAL LAP SPLICES, CIRCUMFERENTIAL SKIN AND STRINGER
SPLICES; 2. AFT ENTRY AND GALLEY DOOR CUTOUT SURROUND STRUCTURE IN LOWER LOBE; 3. STA 1016
BULKHEAD, INCLUDING CHORDS, PRESSURE WEB, STIFFENERS, CHORD/WEB ATTACHMENTS; 4. STRINGER SPLICE
FITTINGS AND TENSION BOLTS AT STA 1016.
53.240 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRS/MSC 5059
AFL 1943
REF: 8TC 53-260-00-01
WO: 144 MOS INSP (212012)
+ 53-360-00 (01) INSPECT (INTERNAL-DETAILED) FORWARD ENTRY DOOR CUTOUT SURROUND STRUCTURE LOOK AT DOOR CUTOUT
TO, AND INCLUDING THE DOORSIDE OF THE FIRST FRAME FROM THE DOOR.
53.335 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSAISC 5059
AFL 1943
REF: 8TC 53-360-00-01
WO: 144 MOS INSP (212012)
(xEXT) - Extension incorporated in the next due (s) - Suppressed Requirement - FAA manual flap Is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
13 Of 42
EFTA00597222
qmpAviaries. frum Mr griramd uj
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
( FAG! A C TIME REMAINING
+ 53-360-00 (02) INSPECT (INTERNAL-DETAILED) FORWARD SERVICE DOOR CUTOUT SURROUND STRUCTURE LOOK AT DOOR
CUTOUT TO, AND INCLUDING THE DOORSIDE OF THE FIRST FRAME FROM THE DOOR.
53.336 MOS 72 30-MAR-2012 30-MAR-2018 238d 304AAR-2018
HRSA1SC 5059
AFL 1943
REF: SIC 53-380-00-02
WO: 144 MOS INSP (2/2012)
+ 53.360-00 (03) INSPECT (INTERNAL-DETAILED) AFT ENTRY DOOR CUTOUT SURROUND STRUCTURE LOOK AT DOOR CUTOUT TO,
AND INCLUDING THE DOORSIDE OF THE FIRST FRAME FROM THE DOOR.
53.340 MOS 72 30-MAR-2012 30-MAR-2018 238d 304AAR-2018
HRS•IISC 5059
AFL 1943
REF: SIC 53-360-00.03
V.10 144 MOS INSP (2/2012)
+ 53-360-00 (04) INSPECT (INTERNAL-DETAILED) AFT SERVICE DOOR CUTOUT SURROUND STRUCTURE LOOK AT DOOR CUTOUT TO,
AND INCLUDING THE DOORSIDE OF THE FIRST FRAME FROM THE DOOR
53.341 MOS 72 30-MAR-2012 30-MAR-2018 238d 304AAR-2018
HRSilISC 5059
AFL 1943
REF: SIC 53-360-00.04
WO 144 MOS INSP (2/2012)
+ 53.380-00 INSPECT (INTERNAL-GENERAL VISUAL) PASSENGER COMPARTMENT FLOOR STRUCTURE IN WET AREA (WITHIN
APPROXIMATELY 20 INCHES FROM DOORS, GALLEYS
AND LAVS AND THE FLOOR STRUCTURE BELOW THE DOOR TO AND
INCLUDING THE FIRST FRAME FROM THE DOOR).
53.350 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSA1SC 5059
AFL 1943
REF: See Worxcard
V.•40 144 MOS INSP (2/2012)
+ 53.814-00 INTERNAL ZONAL INSPECTION (GV) AREA ABOVE FORWARD CARGO COMPARTMENT - SECTION 43, STATION 396 TO
FORWARD CARGO COMPARTMENT AFT BULKHEAD
53.696 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRS'MSC 5059
AFL 1943
REF: SIC S3-814-00-01
WO: 144 MOS INSP (2/2012)
(xEXT) • Extension incorporated in the next due Is) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
14 Of 42
EFTA00597223
qmpAL,iariost frum
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
( ENO) A C. TIME REMAINING
+ 53.820-00 INTERNAL ZONAL INSPECTION (GV) AREA BELOW THE FORWARD CARGO COMPARTMENT - SECTION 43, STATION
396 TO FORWARD CARGO COMPARTMENT AFT BULKHEAD (EZAP)
53.705 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRS:11SC 5059
AFL 1943
REF: BTC 53-820-00-01
190 144 MOS INSP (2/2012)
+ 53.822-00 INTERNAL ZONAL INSPECTION (GV) AIR CONDITIONING DISTRIBUTION BAY - SECTION 43, FORWARD CARGO
COMPARTMENT TO STATION 540 (EZAP)
53.710 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSIISC 5059
AFL 1943
REF: BTC 53.822-00.01
WO 144 MOS INSP (2/2012)
+ 53.826-00 INTERNAL ZONAL INSPECTION (GV) PRESSURE DECK ABOVE THE MAIN LANDING GEAR WHEEL WELL - SECTION 44,
STATION 663.75 TO STATION 727 (EZAP)
53.720 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRS:11SC 5059
AFL 1943
REF: Bit 53.826-00.01
WO: 144 MOS INSP (2/2012)
« 53.832-00 INTERNAL ZONAL INSPECTION (GV) AFT CARGO COMPARTMENT - SECTION 46 AND 47, (PART) STATION 727 TO
STATION 947.5
53.731 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRS:11SC 5059
AFL 1943
REF: Bit 53.832-00.01
WO: 144 MOS INSP (2/2012)
+ 5344040 INTERNAL ZONAL INSPECTION (GV) AREA BELOW THE AFT CARGO COMPARTMENT - SECTION 46 AND 47 (PART),
STATION 727 TO STATION 947.5 (EZAP)
53.745 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRS:MSC 5059
AFL 1943
REF: BTC 53.840-00.01
190. 144 MOS INSP (2/2012)
(xEXT) - Extension incorporated in the next due (s) Suppressed Requirement FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
• - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
15 Of 42
EFTA00597224
qmp Aviaries. frum Mr griramd
Due List
737-73Q83 S/N 29102 (YG001) (N8348Z): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
tENG) Arc TIME REMAINING
+ 57.270-01 INSPECT THE INTERIOR OF LEFT WING TRAILING EDGE CAVITY,
INCLUDING SKINS, RIBS, AILERONS AND SPOILERS.
57.400 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSMSC 5059
AFL 1943
REF: BTC 57-270-01-01
WO 144 MOS INSP (2/2012)
« 57.270.02 INSPECT THE INTERIOR OF RIGHT WING TRAILING EDGE CAVITY,
INCLUDING SKINS, RIBS, AILERONS AND SPOILERS.
57.401 MOS 72 30-MAR-2012 30-MAR-2018 238d 30-MAR-2018
HRSMSC 5059
AFL 1943
REF: BTC 57-270-02-01
WO 1.14 MOS INSP (212012)
SL 737-SL-53-050 POSSIBLE CRACKS IN THE COUNTERSINKS OF FASTNER HOLES COMMON TO FRONT SPAR TO REAR SPAR INFORMATIONAL
UNDERWING PANELS, SERVICE LETTER
MOS 72 30-MAR-2012 30-MAR-2016 238d 30-MAR-2018
HRSi'MSC 5059
AFL 1943
REF: BULLETINS
WO 1.14 MOS INSP (2/2012)
+ 26-020-00 RESTORE LAVATORY SMOKE DETECTOR GRILL BY CLEANING
26.150 MOS 36 22-APR-2015 22-APR-2016 261d 22-APR-2018
HRSMSC 7179.60
AFL 2857
REF: BTC 26.020-00.01
WO: 144 MOS INSP (212012)
26-290-00 INSPECT (DETAILED) CREW, GUEST, AND MASTER LAVATORY WASTE COMPARTMENT FIRE EXTINGUISHING
BOTTLES FOR CORRECT WEIGHT
26.300 MOS 36 22-APR-2015 22-APR-2016 261d 22-APR-2018
HRS/MSC 7179.60
AFL 2857
REF:
V.00 1.14 MOS INSP (2/2012)
« 050040 36 MONTH INSPECTION
MOS 36 CE-MAY-2015 06-MAY-2018 275d 06-MAY-2018
HRS/MSC 7179.60
AFL 2857
REF:
(xEXT) - Extension Incorporated In the next due (s) - Suppressed Requirement +- FAA manual flap is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
© CAMP SYSTEMS
160f 42
EFTA00597225
CAMPAvietiese frvi, **smoothy"
Due List
737-73Q83 S/N 29102 (YG001) (N8348Z): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ESC) A/C TIME REMAINING
25-240-00 (0031) RESTORE AFT ENTRY ESCAPE SLIDE AT THE MANUFACTURER'S RECOMMENDED INTERVAL. RESTORE
P/N: CalN)7.7 MOS 36 06-MAY-2015 06-MAY-2018 275d 06-MAY-2018
HRS/MSC
SIN: BNG1450
AFL
REF: 87C 25-240-00-03
WO: 144 MOS INSP (212012)
257021 CLEAN INSIDE OF SUPPLY AND EXHAUST EIE COOLING DUCTS. CLEAN INSIDE OF COOLING RACK PLENUMS AND
SHELVES (REF: 737SL-25.121)
MOS 36 06-MAY-20I 06-MAY-2018 275d 06-MAY-2018
HRS/MSC
AFL
REF:
WO 144 MOS INSP (2/2012)
28-050-00 OPERATIONAL CHECK OF ENGINE FUEL SUCTION FEED SYSTEM
28.885 MOS 36 06-MAY-2015 06-MAY-2018 275d 06-MAY-2018
FIRS/MSC 7500 7179.60 14679.60 6240.6
AFL 2857
REF: 87C 28-050-00-01
28-AWL-101 OPERATIONAL TEST ENGINE FUEL SUCTION FEED ALI
MOS 36 06-MAY-20I 06-MAY-2018 275d 06-MAY-2018
HRS/MSC 7500 7179.60 14679.60 6240.6
AFL 2857
REF: GENERIC NO REF
32-085-00 DETAILED INSPECTION NOSE LANDING GEAR AXLE
32.656 162A1100-4 MOS 36 (s) 06-MAY-20I5 06-MAY-2018 275d 06-MAY-2018
FIRS/MSC 7179.60
S/N: 19433Y0101
AFL 2857
REF: BTC 32-085-00-01
+ 32-200-00 FUNCTIONAL CHECK OF THE NOSE LANDING GEAR MANUAL EXTENSION SYSTEM.
32.685 MOS 36 (s) 06-MAY-20I5 06-MAY-2018 275d 06-MAY-2018
HRS/MSC 7179.60
AFL 2857
REF: 87C 32-200-00-01
(xEXT) - Extension incorporated in the next due (a) - Suppressed Requirement - FAA manual flag is set (EBY) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
170f 42
EFTA00597226
CAMP
Due List Calendar Section
.tpialing,from the 'rumor<Imp' 737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017 Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ESC) APC TIME REMAINING
32-220-00 (01) FUNCTION CHECK OF THE LEFT MAIN LANDING GEAR MANUAL EXTENSION SYSTEM AND ALTERNATE EXTENSION
BYPASS VALVE.
32.110 MOS 36 (s) 06-MAY-20I5 06-MAY-2018 M 275d 06-MAY-2018
HRS/MSC 7179.60
AFL 2857
REF: 87C 32-220-00-01
32-220-00 (02) FUNCTION CHECK OF THE RIGHT MAIN LANDING GEAR MANUAL EXTENSION SYSTEM AND ALTERNATE EXTENSION
BYPASS VALVE.
32.115 MOS 36 (s) 06-MAY-2015 06-MAY-2018 M 275d 06-MAY-2018
HRS/MSC 7179.60
AFL 2857
REF: 87C 32-220-00-02
32-440-00 DETAILED VISUAL INSPECTION OF THE EXPOSED PORTIONS OF THE LANDING GEAR SYSTEM CONTROL CABLES.
32.150 MOS 36 (s) 06-MAY-2015 06-MAY-2018 M 275d 06-MAY-2018
HRS/MSC 7179.60
AFL 2857
REF: See Wcckcard
+ 32406-01 EXTERNAL ZONAL INSPECTION (GV) LEFT MAIN LANDING GEAR AND LANDING GEAR DOORS. PERFORM AN
EXTERNAL ZONAL INSPECTION (GV) OF THE LEFT MAIN LANDING GEAR AND LANDING GEAR DOORS. (EZAP)
32.855 MOS 36 06-MAY-2015 06-MAY-2018 M 275d 06-MAY-2018
HRS+1.ISC 7179.60
AFL 2857
REF: BIC 32-806-01-01
+ 32-81042 EXTERNAL ZONAL INSPECTION (GV) RIGHT MAIN LANDING GEAR AND LANDING GEAR DOORS. PERFORM AN
EXTERNAL ZONAL INSPECTION (GV) OF THE RIGHT MAIN
LANDING GEAR AND LANDING GEAR DOORS. (EZAP)
32.856 MOS 36 06-MAY-2015 06-MAY-2018 M 275d 06-MAY-2018
HRS/MSC 7179.60
AFL 2857
REF: 87C 32-810-02-01
54-09041 FUNCTIONALLY CHECK THE LEFT ENGINE FORWARD STRUT AND AFT STRUT FAIRING DRAINS.
54.901 MOS 36 C6-MAY-2015 06-MAY-2018 275d 06-MAY-2018
HRS!MSC 7179.60
AFL 9000 2857 11857 8429
REF: 87C 54-090-01-01
WO: 144 MOS INSP (212012)
(xEXT) - Extension incorporated in the next due (a) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
18 Of 42
EFTA00597227
qmp Apialien, /mai the 'rumor<Imp'
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ESC) APC TIME REMAINING
54-09042 FUNCTIONALLY CHECK THE RIGHT ENGINE FORWARD STRUT AND AFT STRUT FAIRING DRAINS.
54.902 MOS 36 06-MAY-2015 06-MAY-2018 275d 06-MAY-2018
HRS(MSC 7179.60
AFL 9000 2857 11857 8429
REF: 8TC 54-090-02-01
WO: 144 MOS INSP (212012)
+ 55-080-01 INSPECT (INTERNAL-GENERAL VISUAL) LEFT HORIZONTAL STABILIZER FRONT SPAR TERMINAL FITTINGS AND
CENTER SECTION FRONT SPAR LUGS-
55.130 MOS 36 06-MAY-2015 08-MAY-2018 275d 06-MAY-2018
HRS(MSC 7179.60
AFL 2857
REF: 8TC 55-080-01-01
WO: 144 MOS INSP (212012)
+ 55-080-02 INSPECT (INTERNAL-GENERAL VISUAL) RIGHT HORIZONTAL STABILIZER FRONT SPAR TERMINAL FITTINGS AND
CENTER SECTION FRONT SPAR LUGS-
55.140 MOS 36 06-MAY-2015 06-MAY-2018 275d 06-MAY-2018
HRS/MSC 7179.60
AFL 2857
REF: 8TC 55-080-02-01
WO: 144 MOS INSP (212012)
+ 55-120-01 INSPECT (INTERNAL-GENERAL VISUAL) LEFT HORIZONTAL STABILIZER REAR SPAR TERMINAL FITTINGS AND
CENTER SECTION REAR SPAR LUGS-
55.330 MOS 36 06-MAY-2015 08-MAY-2018 275d 06-MAY-2018
HRS/MSC 7179.60
AFL 2857
REF: 8TC 55-120-01-01
WO: 144 MOS INSP (2/2012)
+ 55-12042 INSPECT (INTERNAL-GENERAL VISUAL) RIGHT HORIZONTAL STABILIZER REAR SPAR TERMINAL FITTINGS AND
CENTER SECTION REAR SPAR LUGS-
55.340 MOS 36 06-MAY-2015 08-MAY-2018 275d 06-MAY-2018
HRS(MSC 7179.60
AFL 2857
REF: 8TC 55-120-02-01
WO: 144 MOS INSP (212012)
(xEXT) - Extension incorporated in the next due (a) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
19 Of 42
EFTA00597228
qmpAviaries. frum thvgriramd up'
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
( EPIC. ( A C TIME REMAINING
• 57-030-00 INSPECT (EXTERNAL-GENERAL VISUAL) AFT SIDE OF REAR SPAR, INCLUDING KEEL BEAM STIFFENERS AT BL 6.2,
AND SIDE OF BODY REAR SPAR TERMINAL FITTING.
57.050 MOS 36 C6-MAY-2015 06-MAY-2018 275d 06-MAY-2018
HRSIMSC 7179.60
AFL 2857
REF: BTC 57-030-00-01
WO: 144 MOS INSP (2/2012)
FAA 2014-05-27 APPLIANCE AD - NAVIGATION - ROCKWELL COLLINS, INC. TPR-720 AND TPR-900 MODE S TRANSPONDERS - TEST MANDATORY
AND CALIBRATION
MOS 48 14-MAY-2014 14-MAY-2018 283d 14-MAY-2018
HRS4.1SC 6477.10
AFL 2529
REF: AD
26-181-00 (001.1) HYDROSTATIC TEST APU FIRE EXTINGUISHER BOTTLE
26.290 PM: 33000027-1 MOS 120 30-MAY-2008 30-MAY-2018 299d 30-MAY-2018
HRSNASC
S/N: 40279B1
AFL
REF: BTC 26-181-00-01
26-061-00 (001.1) HYDROSTATIC TEST NO. 1 ENGINE FIRE EXTINGUISHER BOTTLE
26.040 PiN: 33700002 MOS 120 02-JUN-2008 02-JUN-2018 302d 02-JUN-2018
HRS•MSC 3714.90
SiN: 31600D1
AFL 1323
REF: BTC 26.061-00.01
26-061-00 (002.1) HYDROSTATIC TEST NO. 2 ENGINE FIRE EXTINGUISHER BOTTLE
26.041 PM: 33700002 MOS 120 02-JUN-2008 02-JUN-2018 302d 02-JUN-2018
HRSiMSC 3714.90
31537D1
AFL 1323
REF: BTC 26-061-00-01
20-141-00 FUNCTIONAL CHECK OF THE LIGHTNING/HIRF PROTECTION COMPONENTS IN THE TAIL CONE FOR
ELECTRICAL BOND DEGRADATION USING THE LOOP RESISTANCE TESTER (LRT). (UHIRF)
MOS 216 30-JUN-2000 30-JUN-2018 330d 30-JUN-2018
1-IRS/MSC 163
AFL 116
REF: BTC 20-141-00.01
(xEXT) • Extension incorporated in the next due (s) • Suppressed Requirement + • FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
20 Of 02
EFTA00597229
qmpAL,iariost frum thvgriramd.p*
Due List
737-73Q83 S/N 29102 (YG001) (N8348Z): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ENG A' C TIME REMAINING
+ 25-410-00 (0031) DISCARD FIRST OBSERVER SMOKE HOOD AT THE MANUFACTURER'S RECOMMENDED INTERVAL UFE LIMIT
PM: PN MOS 120 30-JUN-2018 1.1 330d 30-JUN-2018
HRSilISC
SN-UNKNOWN
AFL
REF: BIC 25-410-00.01
+ 25-410-00 (004.1) DISCARD SECOND OBSERVER SMOKE HOOD AT THE MANUFACTURER'S RECOMMENDED INTERVAL UFE LIMIT
PIN: PN MOS 120 30-JUN-2000 30-JUN-2018 M 330d 30-JUN-2018
HRS MSC 163
S,N: SN-UNKNOWN
AFL 116
REF: BIC 25-410-00.01
25-410-00 (005.0_ FLIGHT ATTENDANT SMOKE HOOD UFE LIMIT
PA: PN MOS 120 30-JUN-2018 M 330d 30-JUN-2018
HRSilISC
S,N: SN-UNKNOWN
AFL
REF:
APH
27-230-00 DETAILED VISUAL INSPECTION OF ALL FLIGHT CONTROL CABLES THAT ARE OVER THE CENTER WING SECTION
B.S. 540 TO 663.75 AND CABLE WITHIN PILOTS CONTROL QUADRANT
27.999 MOS 216 30-JUN-2000 30-JUN-2018 330d 30-JUN-2018
HRS MSC 163
AFL 116
REF: See Workcard
32-460-00 DETAILED VISUAL INSPECTION OF THE INTERNAL PORTIONS OF THE LANDING GEAR SYSTEMS CONTROL CABLES
THAT ARE OVER THE CENTER WING SECTION BS 540 TO BS 727 OR CABLES THAT REQUIRE SPECIAL ACCESS.
32.160 MOS 216 30-JUN-2000 30-JUN-2018 330d 30-JUN-2018
HRS MSC 163
AFL 116
REF: See Workcard
+ 53-350-00 INSPECT (INTERNAL-GENERAL VISUAL) PASSENGER COMPARTMENT FROM STATION 270 TO 360 (EXCEPT AREAS
AROUND DOOR CUTOUTS) INCLUDING SKIN PANELS (SKINS, FRAMES, STRINGERS), LONGITUDINAL LAP SPLICES,
CIRCUMFERENTIAL SKIN AND STRINGER SPLICES.
53.325 MOS 216 30-JUN-2000 30-JUN-2018 330d 30-JUN-2018
HRS MSC 163
AFL 116
REF: BIC 53-350-00.01
(xEXT) • Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
21 Of 42
EFTA00597230
qmes. p
Aviari frum thvgriramd up'
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Operator: FIRST VIRTUAL AIR LLC.
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
CENG ) A/C TIME REMAINING
+ 53-400-00 INSPECT (INTERNAL-GENERAL VISUAL) PASSENGER COMPARTMENT FROM STATION 360 TO 663.75 INCLUDING: 1.
SKIN PANELS (SKINS, FRAMES AND STRINGERS),
LONGITUDINAL LAP SPLICES, CIRCUMFERENTIAL SKIN AND STRINGER SPLICES; 2. WINDOW BELT STRUCTURE; 3.
OVERWING EMERGENCY EXIT CUTOUT STRUCTURE; 4. FORWARD CARGO DOOR CUTOUT SURROUND STRUCTURE
(PORTION IN UPPER LOBE); 5. STA 540 AND 663 BULKHEADS AND SPLICES; 6. OVERWING FRAMES AND STUB
BEAMS
53.355 MOS 216 30-JUN-2000 30-JUN-2018 330d 30-JUN-2018
HRSilISC 163
AFL 116
REF: SIC 53-400-00.01
« 53410-00 INSPECT (INTERNAL-GENERAL VISUAL) PASSENGER COMPARTMENT FROM STATION 663.75 TO 1016 (EXCEPT
AREAS AROUND DOOR CUTOUTS),
53.480 MOS 216 30-JUN-2000 30-JUN-2018 330d 30-JUN-2018
HRSi'MSC 163
AFL 116
REF: BIC 53-410-00-01
534101 INSPECT EXOGRID AT STATION 663.75 (SUPPLEMENT TO BOEING MPD TASK 53410-00)
MOS 216 30-JUN-2000 30-JUN-2018 330d 30-JUN-2018
HRSi'MSC 163
AFL 116
REF:
534102 INSPECT EXOGRID AT STATION 706 (SUPPLEMENT TO BOEING MPD TASK 53410-00)
MOS 216 30-JUN-2000 30-JUN-2018 330d 30-JUN-2018
HRSIMSC 163
AFL 116
REF:
+ 25410-00 (001.1) DISCARD THE PILOT SMOKE HOOD AT THE MANUFACTURER'S RECOMMENDED INTERVAL LIFE LIMIT
PM: PN MOS 120 31-JUL-2018 M 361d 31-JUL-2018
HRSi 1.1SC
S/N: SN-UNKNOWN AFL
REF: SIC 25-410-00-01
ASB 737-26A1137 R1 PERFORM FIRE PROTECTION - CARGO BAY SMOKE DETECTION - EQUIPMENT COOLING SYSTEM SMOKE RECOMMENDED
TBL 1.1 CLEARANCE MODE OPERATIONAL TEST FOR CARGO SMOKE PROTECTION, ALERT SERVICE BULLETIN SMOKE
CLEARANCE MODE - OPERATIONAL TEST (FOR GROUP 1, CNF 1 AIRPLANES)
MOS 51 (EFF) 22-AUG-2018 383d 22-AUG-2018
HRSilISC
AFL
REF: BULLETINS
(xEXT) - Extension incorporated In the next due (s) - Suppressed Requirement + - FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
22 Of 42
EFTA00597231
Due List Calendar Section
CAMPAvis:km.1ns gromod srp' 737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017 Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
CENCI) AIC TIME REMAINING
25410.00 (007.0) FORWARD CABIN EMERGENCY EQUIPMENT CABINET SMOKE HOOD LIFE LIMIT
PIN: MR-10035N MOS 120 TSN:O 23-NOV-2016 22-SEP-2018 M 414d 22-SEP-2018
HRS1MSC 8417.40
SIN: E0800681
AFL 3418
REF:
APH
35.12.85 (4) NO.2 OBSERVER OXYGEN MASK
35.020 PIN: MC10-08-109 MOS I2-JUN-2014 30-SEP-2018 M 422d 30-SEP-2018
HRS1MSC OfC. 6582.60
S/N: 91368
AFL 2568
REF:
FAA 2016-18-01 PARA GENERAL VISUAL INSPECTION OF THE LEFT 8 RIGHT MLG AT THE FORWARD 8 AFT TRUNNION PIN LOCATIONS AND MANDATORY
(H) THE VISIBLE SURFACES FOR SIGNS OF CORROSION OR CHROME PLATING DAMAGE 8 LUBRICATE THE FORWARD
AND AFT TRUNNION PIN ASSEMBLIES AND REPEAT (NC GROUPS 1 8 2 CONFIGURATION 1, NC GROUP 3 IN SB
737.32.1448 R1)
MOS 18 13-APR-2077 13-OCT-2018 4350 13-OCT-2018
HRS1MSC 8422.60
AFL 3420
REF: AD
+ 28-130-00 (001.1) REPLACE EMERGENCY FUEL SHUTOFF BATTERY
28.710 PIN: 2313 MOS 84 31-OCT-2011 31-OCT-2018 453d 31-OCT-2018
HRS1MSC
S/N: 9087
AFL
REF: 8TC 28-130-00-01
WO: 144 MOS INSP (212012)
341105 TEST STANDBY ALTIMETER INDICATOR PER FAR 91.411
34.010 PIN: WL102AMS3 MOS 24 04-JAN-2017 04-JAN-2019 518d 04-JAN-2019
HRS'MSC 8419.20
SIN: AK970
AFL 3419
REF:
WO: 144 MOS INSP (212012)
FAA 2011-27-03 PARA DETAILED INSPECTION TO PREVENT AN UNDETECTED FAILURE OF THE PRIMARY LOAD PATH FOR THE MANDATORY
(G)(1)(I)(1) BALLSCREW IN THE DRIVE MECHANISM OF THE HSTA AND SUBSEQUENT WEAR AND FAILURE OF THE SECONDARY
LOAD PATH IN ACCORDANCE WITH SERVICE BULETIN 737-27A1277 R2
MOS 24 05-JAN-2017 05-JAN-2019 519d 05-JAN-2019
HRS/MSC 6400 8419.20 14819.20 6380.2
AFL 3419
REF: AD
(xEXT) - Extension Incorporated In the next due (a) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
23 Of 42
EFTA00597232
qmpAviaries. frum thvgriramd up*
Due List
737-73Q83 SIN 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ENG A' C
TIME REMAINING
+ 341112 TEST NO. 2 ATC TRANSPONDER PER FAR 91.413
34.451 PA: 822-1338-003 MOS 24 05-JAN-2017 05-JAN-2019 519d 05-JAN-2019
HRSMSC
S:N: 78GD
AFL
REF:
WO: 144 MOS INSP (2/2012)
23-110-00 (001.1) DISCARD (AUTOMATIC/FIXED) EMERGENCY LOCATOR TRANSMITTER BATTERY DISCARD
23.020 MOS 23-NOV-2013 01-FEB-2019 IA 546d 01-FEB-2019
HRSMSC DUE 6129
AFL 2366
REF: EITC 23-110-00-01
+ 341111 TEST NO. 1 ATC TRANSPONDER PER FAR 91.413
34.450 RN: 822-1338-003 MOS 24 22-MAR-2017 22-MAR-2019 595d 22-N1AR-2019
HRSMSC
S,N: MOVR
AFL
REF:
WO: 144 MOS INSP (2/2012)
FAA 2006-21-01 PARA MEASURE THE FREEPLAY OF BOTH AILERON CONTROL BALANCE TABS MANDATORY
(G)
MOS 24 23-MAR-2017 23-MAR-2019 596d 23-N1AR-2019
HRSMSC 8000 8419.20 16419.20 7980.2
AFL 3419
REF:
FAA 2017-04-11 PARA INSPECT THE MLG TO DETERMINE IF IT HAS ANY COMPONENT INSTALLATION OR SIDE STRUT ASSEMBLY HAVING A MANDATORY
(G) PIN AND S/N LISTED IN APPENDIX D OF SB 737-32-1486 AND REVIEW RECORDS TO DETERMINE IF THE MLG HAS
BEEN OVERHAULED BY MESSIER SERVICES ASIA PTE LTD OUTSIDE OF THE BOEING EXCHANGE PROGRAM FROM
JUNE 1, 2009 TO JULY 31, 2013
MOS 24 (EFF) 29-MAR-2019 602d 29-MAR-2019
HRSMSC
AFL
REF: AD
FAA 2017-04-11 PARA DETAILED INSPECTIONS OF THE EXTERNAL SURFACES OF THE MLG AND APPLICABLE RELATED INVESTIGATIVE MANDATORY
(H.1) AND CORRECTIVE ACTIONS (IF ANY AFFECTED PART IS IDENTIFIED DURING THE INSPECTION OR RECORDS REVIEW
REQUIRED BY PARA (G) OF THIS AD)
MOS 24 (EFF) 29-MAR-2019 602d 29-MAR-2019
HRSMSC
AFL
REF: AD
IxEXT) - Extension incorporated in the next due Is) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
20 Of 02
EFTA00597233
4MP
Due List Calendar Section
Ariel.,"I /rum the give:atI tift. 737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017 Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
'ENO) MC TIME REMAINING
FAA 2017-04-11 PARA DETAILED INSPECTION AND BUSHING REPLACEMENT OF THE MLG TRUNNION BORE AND APPLICABLE RELATED MANDATORY
(I) INVESTIGATIVE AND CORRECTIVE ACTIONS (NC IDENTIFIED AS GROUPS 1 AND 2, CONFIGURATION 1, IN SB
737.32.1486 AND THAT HAVE AN AFFECTED PART IDENTIFIED DURING THE INSPECTION OR RECORDS REVIEW
REQUIRED BY PARA (G) OF THIS AD)
MOS 24 (EFF) 29-MAR-2019 6020 29-MAR-2019
HRS/MSC
AFL
REF: AD
FAA 2017-14-13 EQUIPMENT/FURNISHINGS - FLIGHT COMPARTMENT - CAPTAIN'S AND FIRST OFFICER'S RUDDER PEDAL HEEL REST MANDATORY
COVER ASSEMBLY FASTENER TORQUE CHECK AND REPLACEMENT OF THE AFFECTED SCREW AND ASSOCIATED
NUTPLATE
DUE NEXT MOS 21 (EBT) 23-MAY-2019 NEW 23-MAY-2019
HRS/MSC REQMT
AFL
REF: AD
NEW REQUIREMENT ADDED ON 20-JUL-2017 (EFFECTIVE: 23-AUG-2017). REVIEW BASE TIMES TO ENSURE CORRECT DUE TIMES.
ASB 737-56A1022 R1 DETAILED INSPECTION WINDOWS - FLIGHT COMPARTMENT - FLIGHT DECK NUMBER 2, NUMBER 4 AND NUMBER 5 RECOMMENDED
TABLE 1.01 WINDOWS - INSPECTION, ALERT SERVICE BULLETIN OF THE LEFT AND RIGHT FLIGHT DECK NUMBER 2 WINDOW
(GROUP 1-2)
MOS 36 07-JUN-2016 07-JUN-2019 672d 07-JUN-2019
HRS/MSC 7500 8078.60 15578.60 7139.6
AFL 3263
REF: BULLETINS
WO: 144 1,10S INSP (212012)
2544040 (004.1) RESTORE AFT SERVICE ESCAPE SLIDE AT THE MANUFACTURER'S RECOMMENDED INTERVAL. RESTORE
PIN: 5A3307-7 MOS 36 30-SEP-2016 23-SEP-2019 M 780d 23-SEP-2019
HRSIISC
SIN: BNG3285
AFL
REF: SIC 25-240-00-04
WO: 144 MOS INSP (212012)
23-07040 REPLACE COCKPIT VOICE RECORDER LOCATOR BEACON THE ULB BATTERY AT VENDOR'S RECOMMENDATION
23.090 PIN: 2100-1020-00 MOS 24 26-MAR-2016 29-NOV-2019 M 8470 29-NOV-2019
I-IRS/MSC 7963.40
SiN: 000171333
AFL 3184
REF: 8TC 23-070-00-01
WO: 144 MOS INSP (212012)
(xEXT) - Extension incorporated in the next due (s) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
25 Of 42
EFTA00597234
Due List Calendar Section
CAMPAvieties.Irv', voirad 737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017 Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ENO) A/C TIME REMAINING
25-30040 (001.1) RESTORE CREW REST DIVAN LIFE RAFT RESTORE
PM: 64404-10112 MOS 36 16-DEC-2016 16-DEC-2019 8640 16-DEC-2019
HRS1MSC
SiN: 0039
AFL
REF: 8TC 25-300-00-01
WO: 144 MOS INSP (212012)
25-300.00 (002.1) RESTORE UN DINNING EMERGENCY EXIT LIFE RAFT RESTORE
PM: 64404-10114 MOS 36 19-DEC-2016 19-DEC-2019 8670 19-DEC-2019
HRS1MSC
SiN: 0080
AFL
REF: STC 25-300-00-01
WO: 144 MOS INSP (212012)
35-031.00 (001.1) HYDROSTATIC TEST CREW OXYGEN CYLINDER HYDRO CHECK
35.080 PM: 842365-I MOS 36 20-DEC-2016 20-DEC-2019 868d 20-DEC-2019
HRS1MSC
SIN: R12-002232
AFL
REF: See Wakcard
WO: 144 MOS INSP (212012)
53400-00 (SUPP) INSPECT EXO-GRID INTERFACES AT STATION 540 (SUPPLEMENTED TO BOEING TASK 53.400-00)
MOS 144 09-JAN-2008 09-JAN-2020 888d 09-JAN-2020
HRSIISC 3711.70
AFL 1320
REF:
53.410-00 (SUPP) INSPECT EXO-GRID INTERFACES AT STATION 601(SUPPLEMENTED TO BOEING TASK 53400-00)
MOS 144 09-JAN-2008 09-JAN-2020 888d 09-JAN-2020
HRS/MSC 3711.70
AFL 1320
REF:
53-420-00 (SUPP) INSPECT EXO-GRID INTERFACES AT STATION 663.75(SUPPLEMENTED TO BOEING TASK 53.400-00)
MOS 144 09-JAN-2008 09-JAN-2020 888d 09-JAN-2020
HRS1MSC 3711.70
AFL 1320
REF:
53-430-00 (SUPP) INSPECT EXO-GRID INTERFACES AT STATION 706(SUPPLEMENTED TO BOEING TASK 53400-00)
MOS 144 09-JAN-2008 09-JAN-2020 888d 09-JAN-2020
HRSIMSC 3711.70
AFL 1320
REF:
(xEXT) - Extension Incorporated In the next due (s) - Suppressed Requirement +- FAA manual flag is set (EBT) - Estimated Base Time (EPP) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
26 Of 42
EFTA00597235
qmp Arialiom'rpm Mir grown( gep-
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
CENG) AIC TIME REMAINING
25-240-00 (001.1) RESTORE FORWARD ENTRY ESCAPE RESTORE
SLIDE AT THE MANUFACTURER'S RECOMMENDED INTERVAL.
PIN: 5A3307-7 MOS 36 16-JAN-2017 16-JAN-2020 895d 16-JAN-2020
HRS/MSC
SIN: BNG1942
AFL
REF: BTC 25-240-00-01
WO: 144 MOS INSP (2/2012)
25-300-00 (003.1) RESTORE FORWARD CABIN R/H LIFE RAFT RESTORE
PIN: 64404-10112 MOS 36 19-JAN-2017 19-JAN-2020 898d 19-JAN-2020
HRS/MSC
S/N: 0035
AFL
REF: BTC 25-300-00-01
WO: 144 MOS INSP (2/2012)
25-300-00 (004.1) RESTORE L/H LOUNGE DIVAN LIFE RAFT #2 RESTORE
FM: 64404-10112 MOS 36 19-JAN-2017 19-JAN-2020 898d 19-JAN-2020
HRS/MSC
SeN: 0087
AFL
REF: BTC 25-300-00-01
WO 144 MOS INSP (212012)
25-300-00 (005.1) RESTORE L/H LOUNGE DIVAN LIFE RAFT RESTORE
PM: 64404-10112 MOS 36 19-JAN-2017 19-JAN-2020 898d 19-JAN-2020
HRSfMSC
S/N: 0041
AFL
REF: BTC 25-300-00-01
WO: 144 MOS INSP (212012)
35.12.85 (1) CAPTAIN OXYGEN MASK
35.010 P/N: MF20-003 MOS 11-JUN-2014 20-JAN-2020 IA 899d 20-JAN-2020
HRSfMSC Ofe 6572.30
S/N: SE80037
AFL 2562
REF:
35.12.85 (2) FIRST OFFICER OXYGEN MASK
35.010 Pat MF20-003 MOS 11-JUN-2014 20-JAN-2020 IA 899d 20-JAN-2020
HRS/MSC OfC 6572.30
Sat SE80038
AFL 2562
REF:
(xEXT) - Extension incorporated in the next due (a) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
27 Of 42
EFTA00597236
qmp Aviaries. frum thvgriramd up'
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
FAG A 'C.
TIME REMAINING
31.150-00 REPLACE FLIGHT DATA RECORDER LOCATOR BEACON FDR ULB BATTERY AT VENDOR RECOMMENDATION LIFE LIMIT
31.125 PIN: OK120 MOS 23-MAR-2017 02-MAR-2020 941d 02-MAR-2020
HRSilISC DUE 841910
S:9: SC17419
AFL 3419
REF: See Workcard
FAA 2008.11-08 (F) DETAIL INSPECTION DETECT AND CORRECT CRACKING IN THE VINYL INTERLAYER OR DAMAGE TO THE MANDATORY
TABLE 1 STRUCTURAL INNER GLASS PANES OF THE FLIGHT DECK NO.2, NO.4 AND NO.5 WINDOWS FOR CRACKING AND
DAMAGE IN THE VINYL INTERLAYER AND GLASS PANES ON NUMBER 2 WINDOW
MOS 36 23-MAR-2017 23-MAR-2020 962d 23-MAR-2020
HRS,MSC 7500 841920 15919.20 7480.2
AFL 3419
REF: AD
WO 144 MOS INSP (2/2012)
081001 WEIGHT CHECK OF AIRCRAFT
08.010 MOS 36 23-MAR-2017 23-MAR-2020 962d 23-MAR-2020
HRSIMSC 8419.20
AFL 3419
REF:
WO 144 MOS INSP (2/2012)
33-080-01 PERFORM CHECKOUT PROCEDURE ON PULSELIGHT STARLIGHT SYSTEM
MOS 36 23-MAR-2017 23-MAR-2020 962d 23-MAR-2020
HRSIMSC 8419.20
AFL 3419
REF:
WO 144 MOS ASP (2+2012)
28-00-02 PATS INSPECT AFS ELECTRICAL COMPONENT CONNECTORS AND CABLES FOR CHAFFING, FRAYED LEADS, BENT PINS,
CORROSION, CHAFFING AND CONDITION. REPAIR OR REPLACE IF REQUIRED
28.045 MOS 96 30-MAR-2012 30-MAR-2020 969d 30-MAR-2020
HRSA1SC 5059
AFL 1413
REF: See tVorkcard
WO 144 MOS INSP (2/2012)
28-20-02 PATS OPERATIONAL CHECK (FS1,FS2,FS3,FS51, FS52,FS53) OF THE FLOAT SWITCHES BY REMOVING FROM MASTER CELL
AND VERIFY OPERATION WITH OHMMETER.
28.085 MOS 96 30-MAR-2012 30-MAR-2020 969d 30-MAR-2020
HRSilISC 5059
AFL 19.13
REF: See Wirkcard
WO: 144 MOS INSP (2/2012)
(xEXT) - Extension Incorporated in the next due (s) - Suppressed Requirement +- FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
• - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
28 Of 42
EFTA00597237
qmpAL,iariost frum thvgriramd up'
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
( ENG ( A C TIME REMAINING
28-20-024)1 PATS OPERATIONAL CHECK OF THE CENTER WING TANK FLOAT SWITCHES BY REMOVING FROM CENTER WING TANK
(CWT) AND VERIFY OPERATION WITH OHMMETER (FS4/FS5 OR FS6/FS7)
28.086 MOS 96 30-MAR-2012 30-MAR-2020 969d 30-MAR-2020
HRS/MSC 5059
AFL 1943
REF: See Workcard
WO: 144 MOS INSP (2/2012)
28-AWL-01 PATS DETAILED INSPECTION OF THE CRITICAL AU
WIRE HARNESS SEPARATION, BRACKETS, CLAMPS,
SHIELDING, SHIELDING TERMINATION POINTS,
DIELECTRIC SLEEVING, AND ROUTING (EWIS)
28.146 MOS 96 30-MAR-2012 30-MAR-2020 969d 30-MAR-2020
HRSAISC 5059
AFL 1943
REF: See Workcard
WO: 144 MOS INSP (2/2012)
28-AWL-03 PATS DETAILED INSPECTION OF DRY BAY WIRING HARNESS ROUTING, CLAMPING, AND ATTACHING BRACKETS FOR AU
CONTAMINATION BY FUEL OR FUEL VAPOR, PHYSICAL DAMAGE, CRACKING AND SECURITY. INSPECT DRY BAY
VALVE ACTUATORS FOR SIGNS OF OVERHEATING, PHYSICAL DAMAGE, OR CRACKING. INSPECT DRY BAY DUAL
REDUNDANT BONDING JUMPERS FOR CORROSION, MECHANICAL WEAR, FRAYING AND SECURITY (EWIS)
28.154 MOS 96 30-MAR-2012 30-MAR-2020 969d 30-MAR-2020
HRSAISC 5059
AFL 1943
REF: See Workcard
WO: 144 MOS INSP (2/2012)
28-AWL-05 PATS DETAILED INSPECTION OF THE BLEED AIR SOLENOID VALVE, DUAL CHECK VALVE, VENTURI AND PLUMBING FOR ALI
DETERIORATION, CORROSION, EVIDENCE OF OVERHEATING OR LEAKAGE. INSPECT IMMEDIATE SURROUNDING
STRUCTURE FOR SIGNS OF HEAT DAMAGE AND/OR DISCOLORATION DUE TO HEAT DAMAGE.
28.159 MOS 96 30-MAR-2012 30-MAR-2020 969d 30-MAR-2020
HRSilISC 5059
AFL 1943
REF: See Workcerd
WO: 144 MOS INSP (2/2012)
(xEXT) • Extension incorporated in the next due Is) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
29 Of 42
EFTA00597238
qmp
A,,iatiostfrum Mrgr./rid uA
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
(Sit ) Art TIME REMAINING
28-AWL-06 PATS DETAILED INSPECTION OF CWT (AFS) ASSOCIATED EQUIPMENT) WIRING HARNESS ROUTING, CLAMPING, AND NJ
ATTACHING BRACKETS FOR PHYSICAL DAMAGE, CRACKING, AND SECURITY. (EWIS)
INSPECT CENTER WING TANK FILL VALVE ACTUATORS FOR SIGNS OF OVERHEAT,PHYSICAL DAMAGE, OR
CRACKING.
INSPECT CENTER WING TANK UPPER AND LOWER FLOAT SWITCHES FOR SECURITY,PHYSICAL DAMAGE, CRACKING
OR LEAKAGE.
INSPECT CENTER WING TANK (AFS ASSOCIATED) DUAL REDUNDANT BONDING JUMPERS FOR CORROSION,
MECHANICAL WEAR, FRAYING AND SECURITY.
28.163 MOS 96 30-MAR-2012 30-MAR-2020 969d 30-MAR-2020
HRSilISC 5059
AFL 1943
REF: See Workcard
WO 144 MOS INSP (2/2012)
25.290-00.26 OFFICE SEAT NO. 20 LIFE VEST RESTORE
PM: P0723E105P MOS 120 TSN:0 28-JAN-2016 18-JUL-2020 PA 1079d 18-JUL-2020
HRS MSC 7807.80
S84: 15070270574
AFL 3122
REF:
25-290-00-27 OFFICE SEAT NO. 23 LIFE VEST RESTORE
P0723E 105P MOS 120 TSN:0 28-JAN-2016 18-JUL-2020 M 1079d 18-JUL-2020
HRSi MSC 7807.80
SM: 15070270219
AFL 3122
REF:
26351-00 (001.1) HYDROSTATIC TEST (LRD2) CARGO HALON FIRE EXTINGUISHER BOTTLE RESTORE
26.035 PM: 473957 MOS 120 19-JUL-2010 19-JUL-2020 1080d 19-JUL-2020
HRS/MSC
SM: 57565EL
AFL
REF: BTC 26-351-00-02
WO: 144 MOS INSP (2/2012)
20-040-05 FUNCTIONALLY CHECK THE LIGHTNING/HIRF PROTECTION COMPONENTS (BY PERFORMING A LOOP RESISTANCE
TEST) IN THE LEFT AND RIGHT WING TO BODY FAIRING ASSOCIATED WITH DISCONNECT BRACKETS AC0520 AND
AD0520 FOR BOND DEGRADATION.
MOS 48 (EFF) 01-DEC-2020 1215d 01-DEC-2020
HRSilISC
AFL
REF: See Workcard
1xE XI) • Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
30 Of 02
EFTA00597239
qmp AL,iariost frum thvgriramd up*
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ENG A' C TIME REMAINING
25-290-00-25 DINNING ROOM SEAT NO. 19 LIFE VEST RESTORE
PIN: R55.301 MOS 120 TSN:12 08-FEB-2012 08-FEB-2021 1284d 08-FEB-2021
HRSilISC 5059
Sa..1: 62799
AFL 1943
REF:
350451 (001.1) HYDROSTATIC TEST NO. 1 PASSENGER OXYGEN CYLINDER RESTORE
35.176 PiN: 897-98015 MOS 60 26-MAR-2016 26-MAR-2021 13300 26-MAR-2021
HRSAISC
Sat ALT282-23064
AFL
REF: See Workcard
WO 144 MOS INSP (2/2012)
350451 (002.1) HYDROSTATIC TEST NO. 2 PASSENGER OXYGEN CYLINDER RESTORE
35.181 PM: 897-98015 MOS 60 26-MAR-2016 26-MAR-2021 13300 26-MAR-2021
HRSilISC
• ALT282-33194
AFL
REF: See Workcerd
WO: 144 MOS INSP (2/2012)
350451 (003.1) HYDROSTATIC TEST NO. 3 PASSENGER OXYGEN CYLINDER RESTORE
PM: 897-98015 MOS 60 26-MAR-2016 26-MAR-2021 1330d 26-MAR-2021
HRS,MSC
• ALT282-17268
AFL
REF: See Workcard
WO: 144 MOS INSP (2/2012)
350451 (004.1) HYDROSTATIC TEST NO. 4 PASSENGER OXYGEN CYLINDER RESTORE
PM: 897-98015 MOS 60 26-MAR-2016 26-MAR-2021 1330d 26-MAR-2021
HRVMSC
SIN: ALT282-23560
AFL
REF: See Workcard
WO: 144 MOS INSP (2/2012)
+ 53-450-00 INSPECT (INTERNAL-GENERAL VISUAL) FUSELAGE SKIN UNDER DORSAL FIN AND AFT TO STATION 1016 INCLUDING
CIRCUMFERENTIAL SPLICE
53.500 MOS 108 30-MAR-2012 30-MAR-2021 1334d 30-MAR-2021
HRSMSC 5059
AFL 1943
REF: BIC 53-450-00-01
WO: 144 MOS INSP (2/2012)
(xE XI) • Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
31 Of 42
EFTA00597240
qmpAviaries. frum Mr griramd
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
I FAG A 'C.
TIME REMAINING
+ 53460-00 INSPECT (INTERNAL-GENERAL VISUAL) VERTICAL FIN FRONT SPAR FITTING LUGS AND BOLTS (STATION 1016)
53.505 MOS 108 30-MAR-2012 30-MAR-2021 1334d 30-MAR-2021
HRSilISC 5059
AFL 1943
REF: BTC 53-46o-oco 1
WO 144 MOS INSP (212012)
+ 53480-00 INSPECT (INTERNAL-GENERAL VISUAL) VERTICAL FIN REAR SPAR FITTING LUGS AND BOLTS (STATION 1088)
INSPECT FUSELAGE SKIN UNDER VERTICAL FIN FROM
STA 1016 TO 1088.
53.511 MOS 108 30-MAR-2012 30-MAR-2021 1334d 30-MAR-2021
HRS!MSC 5059
AFL 1943
REF: Bit 53-480-00.01
V.I0 144 MOS INSP (2/2012)
+ 55-030-00 INSPECT (INTERNAL-GENERAL VISUAL) THE FORWARD SIDE OF THE VERTICAL FIN FRONT SPAR,
INCLUDING FRONT SPAR CHORDS, WEBS, AND TERMINAL FITTINGS
55.080 MOS 108 30-MAR-2012 30-MAR-2021 1334d 30-MAR-2021
HRSi'MSC 5059
AFL 1943
REF: BIC 55.030-00.01
WO 144 MOS INSP (2/2012)
+ 55-050-00 INSPECT (INTERNAL-GENERAL VISUAL) VERTICAL FIN FROM FRONT SPAR TO REAR SPAR INCLUDING
SPAR CHORDS AND WEBS, INSPAR SKINS, LOWER CLOSURE RIB, AND REAR SPAR TERMINAL FITTINGS.
55.090 MOS 108 30-MAR-2012 30-MAR-2021 1334d 30-MAR-2021
HRSi'MSC 5059
AFL 1943
REF: Bit 55.050-00.01
V.I0 144 1.10S INSP (2/2012)
+ 55-070-01 INSPECT (INTERNAL-GENERAL VISUAL) LEFT HORIZONTAL STABILIZER FORWARD SIDE FRONT SPAR, INCLUDING
FRONT SPAR CHORDS AND WEBS, TERMINAL FITTINGS AND CENTER SECTION FRONT SPAR LUGS
55.110 MOS 108 30-MAR-2012 30-MAR-2021 1334d 30-MAR-2021
HRSi'MSC 5059
AFL 1943
REF: BIC SS-070-01-0i
WO: 144 MOS INSP (2/2012)
IxEXT) - Extension incorporated in the next due Is) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
32 Of 42
EFTA00597241
CAMP
Due List Calendar Section
.tpialing,from the 'rumor<Imp' 737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017 Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
10401 AIC TIME REMAINING
+ 55-070-02 INSPECT (INTERNAL-GENERAL VISUAL) RIGHT HORIZONTAL STABILIZER FORWARD SIDE OF FRONT SPAR,
INCLUDING FRONT SPAR CHORDS AND WEBS, TERMINAL FITTINGS AND CENTER SECTION FRONT SPAR LUGS
55.120 MOS 108 30-MAR-2012 30-MAR-2021 13340 30-MAR-2021
HRSA1SC 5059
AFL 19.13
REF: STC 55-070-02-01
WO: 144 MOS INSP (212012)
+ 55-10041 INSPECT (INTERNAL-GENERAL VISUAL) LEFT HORIZONTAL STABILIZER FROM FRONT SPAR TO REAR
SPAR-INCLUDING SPAR CHORDS, WEBS, TERMINAL FITTINGS, UPPER
AND LOWER INSPAR SKINS.
55.150 MOS 108 30-MAR-2012 30-MAR-2021 13340 30-MAR-2021
HRSAISC 5059
AFL 1943
REF: 8TC 55-100-01-01
WO: 144 MOS INSP (212012)
+ 55-10042 INSPECT (INTERNAL-GENERAL VISUAL) RIGHT HORIZONTAL STABILIZER FROM FRONT SPAR TO REAR
SPAR-INCLUDING SPAR CHORDS, WEBS, TERMINAL FITTINGS, UPPER
AND LOWER INSPAR SKINS
55.160 MOS 108 30-MAR-2012 30-MAR-2021 1334d 30-MAR-2021
HRS/MSC 5059
AFL 1943
REF: 8TC 55-100-02-01
WO: 144 MOS INSP (2/2012)
+ 55-11041 INSPECT (INTERNAL-GENERAL VISUAL) LEFT AFT SIDE OF LEFT HORIZONTAL STABILIZER REAR SPAR,
INCLUDING SPAR CHORDS AND WEBS, TERMINAL FITTINGS, ELEVATOR TAB ACTUATOR SUPPORT FITTING, CENTER
SECTION REAR SPAR LUGS, ELEVATOR HINGE RIBS, AND ELEVATOR TAB LEADING EDGE.
55.310 MOS 108 30-MAR-2012 30-MAR-2021 1334d 30-MAR-2021
HRS:MSC 5059
AFL 1943
REF: 8TC 55-110-01-01
WO: 144 MOS INSP (212012)
+ 55-11042 INSPECT (INTERNAL-GENERAL VISUAL) RIGHT AFT SIDE OF RIGHT HORIZONTAL STABILIZER REAR SPAR,
INCLUDING SPAR CHORDS AND WEBS, TERMINAL FITTINGS, ELEVATOR TAB ACTUATOR SUPPORT FITTING, CENTER
SECTION REAR SPAR LUGS, ELEVATOR HINGE RIBS, AND ELEVATOR TAB LEADING EDGE.
55.320 MOS 108 30-MAR-2012 30-MAR-2021 1334d 30-MAR-2021
HRS1MSC 5059
AFL 1943
REF: 8TC 55-110-02-01
WO: 144 MOS INSP (212012)
(xEXT) - Extension incorporated in the next due (a) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
33 Of 42
EFTA00597242
qmp Apialien, /mai the 'rumor<Imp'
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
CENCI) AIC TIME REMAINING
55-11541 DETAILED - INTERNAL LEFT ELEVATOR TAB MECHANISM SUPPORT FITTINGS ON
ELEVATOR FRONT SPAR AND ELEVATOR TAB SPAR AT LEADING EDGE CUTOUTS.
55.880 MOS 108 30-MAR-2012 30-MAR-2021 13340 30-MAR-2021
HRSilISC 5059
AFL 1943
REF: 8TC 55-115-01-01
WO: 144 MOS INSP (212012)
55-11542 DETAILED - INTERNAL RIGHT ELEVATOR TAB MECHANISM SUPPORT FITTINGS ON
ELEVATOR FRONT SPAR AND ELEVATOR TAB SPAR AT LEADING EDGE CUTOUTS.
55.900 MOS 108 30-MAR-2012 30-MAR-2021 13340 30-MAR-2021
HRS'hISC 5059
AFL 1943
REF: I3TC 55-115-02-Of
WO: 144 MOS INSP (212012)
SB 737-34-2454 R2 NAVIGATION - AIR DATA SYSTEM - ALTIMETRY SYSTEM TEST, SERVICE BULLETIN RECOMMENDED
MOS 36 (s) OS-MAY-2021 1.1 13700 05-MAY-2021
HRS1MSC
AFL
REF: BULLETINS
33-070-01 REPLACE CAPTAIN AND F/O MASTER WARNING RECALL ANNUNCATOORS
MOS 72 06-MAY-2015 06-MAY-2021 13710 06-MAY-2021
HRS/MSC 7179.60
AFL 2857
REF:
+ 38-040-00 RESTORE WASTE DRAIN BALL VALVE THE WASTE DRAIN BALL-VALVE BY REPLACING SEALS (2) (OFF AIRCRAFT)
38.130 PIN: 2651-278-21 MOS 72 06-MAY-2015 06-MAY-2021 13710 06-MAY-2021
HRSNISC 7179.60
SiN: 0104
AFL 2857
REF: I3TC 38-040-00-01
WO: 144 MOS INSP (212012)
26-330-00 (003.1) REPLACE (LRD1) CARGO FIRE EXTINGUISHER BOTTLE FORWARD SQUIB UFE LIMIT
26.036 PIN: M446616 MOS 120 01-JUN-2011 01-JUN-2021 1397d 01-JUN-2021
HRS1MSC
SiN: 00691
AFL
REF: BTC 26-330-00-02
(xEXT) - Extension incorporated in the next due (a) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
34 Of 42
EFTA00597243
qmpAL,iariost frum /Arvin/old .4,*
Due List
737-73Q8.1 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Calendar Section
Projected To: 48 MOS. to 04-AUG-2021
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ENG A' C TIME REMAINING
ASB 737-21A1203 AIR CONDITIONING - PACK FLOW CONTROL AND PACK COOLING SYSTEM - LEFT TEMPERATURE CONTROL VALVE RECOMMENDED
AND CONTROL CABIN TRIM AIR MODULATING VALVE REPLACEMENT, ALERT SERVICE BULLETIN
MOS 60 (EFF) 08-JUN-2021 1404d 08-JUN-2021
HRS%ISC
AFL
REF: BULLETINS
+ 53-470-00 INSPECT (INTERNAL-GENERAL VISUAL) VERTICAL FIN FRONT SPAR FITTING LUGS AND BOLTS (STATION 1016)
53.510 MOS 252 30-JUN-2000 30-JUN-2021 1426d 30-JUN-2021
HRSAISC 163
AFL 116
REF: BTC 53-470-00.01
26-33040 (002.1) REPLACE (LRD2) CARGO FIRE EXTINGUISHER BOTTLE AFT SQUIB UFE LIMIT
26.035 P/N: M446617 MOS 120 0I-JUL-2011 01-JUL-2021 1427d 01-JUL-2021
HRSMSC
S/N: 00668
AFL
REF: 8TC 26-330-00-02
26.33040 (004.1) REPLACE (LRD1) CARGO FIRE EXTINGUISHER BOTTLE AFT SQUIB UFE LIMIT
26.036 PIN: M446617 MOS 120 01-JUL-2011 01-JUL-2021 1427d 01-JUL-2021
HRSilISC
Sat 00701
AFL
REF: BTC 26-330-00.02
26-330-00 (001.1) REPLACE (LRD2) CARGO FIRE EXTINGUISHER BOTTLE FORWARD SQUIB UFE LIMIT
26.035 PIN: M446616 MOS 120 01-AUG-2011 01-AUG-2021 1458d 01-AUG-2021
HRSilISC
S,N: 00687
AFL
REF: BTC 26-330-00.02
(xEXT) • Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF)-Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
35 Of 12
EFTA00597244
CAMP
Due List Hours Section
.tpialing,from the 'rumor<Imp' 737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
ENO) AIC TIME REMAINING
21.150-00 (SUPP) CLEAN/REPLACE CABIN TEMPERATURE MODULE FILTER
MOS 25-SEP-2016 28-NOV-2017
HRS/MSC 200 8286.70 8486.70 47.7
AFL 3361
REF:
WO: 144 MOS INSP (212012)
+ 72-4 NO. 1 ENGINE - INSPECT MAGNETIC CHIP DETECTORS ETOPS
MOS 23-MAR-2017 16-DEC-2017
HRS/MSC 75 8419.20 (8194.20) 55.2
ENC 3419 8194.20
REF: ETOPS 72-4
+ 72-4 NO. 2 ENGINE • INSPECT MAGNETIC CHIP DETECTORS ETOPS
MOS 23-MAR-2017 16-DEC-2017
HRSOASC 75 8419.20 (8194.20) 55.2
ENC 3419 8194.20
REF: ETOPS 72-4
+ 73-020-01 INTERROGATE THE FMC CDU FOR LEFT ENGINE FAULTS
73.130 MOS 23-MAR-2017 16-JUN-2018
HRS(MSC I50 8419.20 8569.20 130.2
AFL 3419
REF: 8TC 73-020-01-01
WO: 144 MOS INSP (212012)
+ 73-020-02 INTERROGATE THE FMC CDU FOR RIGHT ENGINE FAULTS
73.140 MOS 23-MAR-2017 16-JUN-2018
HRS(MSC I50 8419.20 8569.20 130.2
AFL 3419
REF: 8TC 73-020-02-01
WO 144 MOS INSP (2/2012)
* 29-030-01 REPLACE "A" HYDRAULIC SYSTEM ELECTRIC MOTOR DRIVEN PUMP (EMDP) CASE DRAIN FILTER
29.190 MOS 08-DEC-2015 11-SEP-2018
HRS(MSC 900 7704.90 8604.90 165.9
AFL 3071
REF: 8TC 29-030-01-01
WO: 144 MOS INSP (212012)
(xEXT) - Extension incorporated in the next due (s) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
36 Of 42
EFTA00597245
qmp AL,iariost frum thvgnmend up*
Due List
737-73Q83 S/N 29102 (YG001) (N8348Z): 8439 HRS, 3428 AFL as of 01-Aug-2017
Hours Section
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
1001,11C TIME REMAINING
+ 29-030-02 REPLACE "B" HYDRAULIC SYSTEM ELECTRIC MOTOR DRIVEN PUMP (EMDP) CASE DRAIN FILTER
29.200 MOS 08-DEC-2015 11-SEP-2018
HRSA1SC 900 7704.90 8604.90 165.9
AFL 3071
REF: BTC 29-030-02-01
WO 144 MOS INSP (212012)
« 71-010-01 DETAILED INSPECTION OF THE LEFT INLET COWL'S INNER SURFACE
71.080 MOS 08-DEC-2015 11-SEP-2018
HRSikISC 900 7704.90 8604.90 165.9
AFL 3071
REF: BIC 71.010-01-01
YVO. 144 MOS INSP (2+2012)
+ 71-010-02 DETAILED INSPECTION OF THE RIGHT INLET COWL'S INNER SURFACE
71.081 MOS 08-DEC-2015 11-SEP-2018
HRSA1SC 900 7704.90 8604.90 165.9
AFL 3071
REF: BIC 71.010-02-01
WO: 144 MOS INSP (212012)
FAA 2011.12.13 PARA TEST TO DETECT AND CORRECT A TAKEOFF WARNING SYSTEM SWITCH FAILURE THE STABILIZER TAKEOFF MANDATORY
(G) WARNING SWITCHES
MOS 19-FEB-2016 2•1-NOV-2018
HRSA1SC 750 7885 20 8635.20 196.2
AFL 3147
REF: AD
WO: 144 MOS INSP (212012)
SB 737.27.1289 737 STABILIZER TAKEOFF WARNING SWITCHES - TEST OF THE TAKEOFF WARNING INDICATION, SERVICE BULLETIN RECOMMENDED
DAYS 19-FEB-2016 2•1-NOV-2018
HRSA1SC 750 7885.20 8635.20 196.2
AFL 3147
REF: BULLETINS
WO: 144 MOS INSP (212012)
27-16240 OPERATIONALLY CHECK THE FLAP SKEW AND FLAP ASYMMETRY SYSTEMS BY INITIATING A BITE CHECK OF THE
FLAP/SLAT ELECTRONICS UNIT (FSEU)
27.990 MOS 29-FEB-2016 26-JAN-2019
HRSMSC 750 7911.20 8661.20 222.2
AFL 3159
REF: BTC 27-162-00-01
WO: 144 MOS INSP (2/2012)
(xE XI) • Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
' - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
37 Of 42
EFTA00597246
qmp Aialio• /rpm thanwerd
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Hours Section
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
cm) Arc TIME REMAINING
+ 23-04040 OPERATIONAL CHECK OF THE VOICE RECORDER AND RECORDER INDEPENDENT POWER
SUPPLY (RIPS) (IF INSTALLED).
23.070 MOS 23-MAR-2017 I 6-JUN-2019
HRSAISC 300 8419.20 8719.20 280.2
AFL 3419
REF: SIC 23-040-00-01
WO: 144 MOS INSP (212012)
+ 27.216-00 FUNCTIONAL CHECK THE AUTOSLAT SYSTEM.
27.655 MOS II-SEP-2015 22-JUN-2019
HRS/MSC 1250 7471.70 8721.70 282.7
AFL 2971
REF: SIC 27-216-00-01
WO: 144 MOS INSP (212012)
+ 27-22440 OPERATIONAL CHECK LEADING EDGE DEVICES UNCOMMANDED MOTION PROTECTION USING STANDBY
HYDRAULIC SYSTEM
27.675 MOS 11-SEP-2015 22-JUN-2019
HRS1MSC 1250 7471.70 8721.70 282.7
AFL 2971
REF: SIC 27-224-00-01
WO: 144 MOS INSP (212012)
33-00041 CHECK STROBE LIGHT FOR CLEANLINESS, SPECIFIED FLASH RATE AND LIGHT INTENSITY PER BOEING 737 TASK
33.44.00.710.801
MOS 26-MAR-2016 02-0CT-2019
FIRSAISC 800 7963.40 8763.40 324.4
AFL 3184
REF:
WO: 144 MOS INSP (212012)
C 285001 TEST EXTRACTED DETECTION SAMPLE FOR MICROBIAL GROWTH
MOS 6 23-MAR-2017 23-SEP-2017 50d 23-SEP-2017
HRSAISC 400 8419.20 8819.20 380.2
AFL 3419
REF:
WO: 144 MOS INSP (212012)
+ 24-02041 DETAIL INSPECTION LEFT INTEGRATED DRIVE GENERATOR OF LEFT IDG DELTA P INDICATOR
24.140 FIN: 761574 MOS 23-MAR-2017 15-FEB-2020
HRS1MSC 400 8419.20 8819.20 380.2
SIN: 1526
AFL 3419
REF: SIC 24-020-01-01
WO: 144 MOS INSP (212012)
(xEXT) - Extension incorporated in the next due (s) - Suppressed Requirement +- FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement) C - Task also due In calendar due list
CAMP SYSTEMS
38 Of 42
EFTA00597247
Due List Hours Section
CAMPAvietiagns tittgromodwp. 737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
CENG) APC TIME REMAINING
+ 24-02042 DETAIL INSPECTION RIGHT INTEGRATED DRIVE GENERATOR OF RIGHT IDG DELTA P INDICATOR
24.150 PM: 761574 MOS 23-MAR-2017 IS-FEB-2020
HRS/MSC 400 8419.20 8819.20 380.2
S/N: 0348
AFL 3419
REF: 87C 24-020-02-01
WO: 144 MOS INSP (212012)
+ 24-030-01 DETAIL INSPECTION LEFT INTEGRATED DRIVE GENERATOR OF LEFT IDG OIL LEVEL
24.160 P/N: 761574 MOS 23-MAR-2017 IS-FEB-2020
HRS/MSC 400 8419.20 8819.20 380.2
SiN: 1526
AFL 3419
REF: 87C 24-030-01-01
WO: 144 MOS INSP (212012)
+ 24-030-02 DETAIL INSPECTION RIGHT INTEGRATED DRIVE GENERATOR OF RIGHT IDG OIL LEVEL
24.170 PM: 761574 MOS 23-MAR-2017 IS-FEB-2020
HRS/MSC 400 8419.20 8819.20 380.2
SiN: 0348
AFL 3419
REF: 87C 24-030-02-01
WO: 144 MOS INSP (212012)
38-01140 DISINFECT POTABLE WATER SUPPLY SYSTEM
MOS 23-MAR-2017 IS-FEB-2020
HRS/MSC 400 8419.20 8819.20 380.2
AFL 3419
REF:
WO: 144 MOS INSP (212012)
+ 27464-00 OPERATIONAL CHECK THE FLAP UN COMMANDED MOTION PROTECTION SYSTEM BY
INITIATING A BITE CHECK OF THE FLAP SLAT ELECTRONICS UNIT.
27.550 MOS 14-FEB-2005 07-JUL-2020
HRS/MSC 6000 2878.25 8878.25 439.25
AFL 1003
REF: 87C 27-164-00-01
+ 72-320-01 NO. 1 ENGINE - DETAILED INSPECTION OF THE ENGINE FWD SUMP, AFT SUMP, AGB/TGB MAGNETIC CHIP
DETECTORS OR DEBRIS MONITORING SYSTEM DETECTORS AND SCAVENGE SCREENS FOR PARTICLES.
MOS 23-MAR-2017 15-OCT-2020
HRS/MSC 500 8419.20 (8919.20) 480.2
ENC 3419 8919.20
REF: See Waimea!
WO: 144 MOS INSP (212012)
(xEXT) - Extension incorporated in the next due (a) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
39 Of 42
EFTA00597248
qmpAviaries. frum Mrgr./Ad uA
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Hours Section
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
I ENGJ A ' C. TIME REMAINING
+ 72.320-01 NO. 2 ENGINE - DETAILED INSPECTION OF THE ENGINE FWD SUMP, AFT SUMP, AGB/TGB MAGNETIC CHIP
DETECTORS OR DEBRIS MONITORING SYSTEM DETECTORS AND SCAVENGE SCREENS FOR PARTICLES.
MOS 23-K1AR-2017 15-OCT-2020
HRSIISC 500 841920 (8919.20) 480.2
ENC 3419 8919.20
REF: See Workcard
WO: 144 MOS INSP (2/2012)
FAA 1974-08-09 R3 LAVATORY PAPER OR LINEN WASTE RECEPTACLE FIRE PREVENTION MANDATORY
MOS 26-MAR-2018 03-FEB-2021
HRSikiSC 1000 7964.90 8964.90 525.9
AFL 3184
REF: AD
26-13-01 FUNCTIONALLY CHECK EXTINGUISHER MONITOR UNIT PER WALTER KIDDE DOCUMENT R-6179 OR R-6664,
PARAGRAPH 5.7 FOR HOLLINGSEAD INSTALLED FIRE BOTTLE (HIGH RATE DISCHARGE)
26.065 MOS 30-JUN-2006 03-JUN-2021
HRSAISC GOOD 3014.30 9014.30 575.3
AFL 1084
REF: See Workcard
(xEXT) • Extension incorporated in the next due (s) Suppressed Requirement + FAA manual flag is set (EBT) - Estimated Base Time (EFF) -Effective CM
' - Estimated Due (applies to New Requirement)
0 CAMP SYSTEMS
40 Of 42
EFTA00597249
4MP
i•liorI /r give:atI tift.
Due List
737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
AFL Section
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04-AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE
MAX LIMIT DISPOSITION EST. DUE
MC) AIC
TIME REMAINING
FAA 2013-08-15 PARA EXTERNAL - DETAILED INSPECTION REPETITIVE INSPECTIONS/REPAIR FOR CRACKING OF THE FUSELAGE SKIN MANDATORY
(G) ALONG CHEM-MILL STEPS AT CERTAIN CROWN SKIN AND SHEAR WRINKLE AREAS AND AN EXTERNAL
NONDESTRUCTIVE INSPECTION FOR CRACKING IN THE FUSELAGE SKIN ALONG THE CHEM-MILL STEPS AT CERTAIN
(CROWN SKIN) LOCATIONS
MOS (EFF) 28-FEB-2020
HRS/MSC
AFL 1500 3625 197
REF: AD
FAA 2013-08-16 PARA EXTERNAL - DETAILED INSPECTION FUSELAGE - REPETITIVE INSPECTIONS/REPAIR FOR CRACKING OF THE MANDATORY
(G) FUSELAGE SKIN AT CERTAIN LOCATIONS AT CHEM-MILL AREAS AND AN EXTERNAL NONDESTRUCTIVE INSPECTION
FOR CRACKING IN THE FUSELAGE SKIN ALONG THE CHEM-MILL STEPS AT CERTAIN LOCATIONS
MOS (EFF) 28-FEB-2020
HRS/MSC
AFL 1500 3625 197
REF: AD
(xEXT) - Extension incorporated in the next due (a) - Suppressed Requirement - FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement)
CAMP SYSTEMS
41 Of 02
EFTA00597250
CAMP
Due List Special Requirements Section
.tpialing,from the 'rumor<Imp' 737-73Q83 S/N 29102 (YG001) (N83482): 8439 HRS, 3428 AFL as of 01-Aug-2017
Operator: FIRST VIRTUAL AIR LLC. Report Date: 04AUG-2017
TASK NO TASK DESCRIPTION UNIT INTERVAL TIME SINCE COMPLIANCE NEXT DUE MAX LIMIT DISPOSITION EST. DUE
CENCI) AIC TIME REMAINING
C 28-AWL-19 REVIEW CENTER TANK FUEL BOOST PUMP AUTOMATIC SHUTOFF SYSTEM ALI
28.205 MOS 12 23-MAR-2017 23-MAR-2018 231d 23-MAR-2018
HRS(MSC 8419.20
AFL 3419
REF: See Wakcard
(xEXT) - Extension incorporated in the next due (s) - Suppressed Requirement +- FAA manual flag is set (EBT) - Estimated Base Time (EFF) - Effective CM
• - Estimated Due (applies to New Requirement) C - Task also due In calendar due list
CAMP SYSTEMS
42 Of 42