SOFTWARE HOUSE
From Tyco Security Products
C•CURE 9000
Version 2.50
EFTA01224570
C•CURE and Software House are registered trademarks of Tyco Security Products.
The trademarks, logos, and service marks displayed on this document are registered in the
United State [or other countries]. Any misuse of the trademarks is strictly prohibited and Tyco
Security Products will aggressively enforce its intellectual property rights to the fullest extent of
the law, including pursuit of criminal prosecution wherever necessary. MI trademarks not
owned by Tyco Security Products are the property of their respective owners, and are used with
permission or allowed under applicable laws.
Product offerings and specifications are subject to change without notice. Actual products may
vary from photos. Not all products include all features. Availability varies by region; contact
your regional sales manager.
C•CURE 9000 Software version: 250
Document Number: UM-279
Revision Number: HO
Release Date: December 2015
This manual is proprietary information of Software House. Unauthorized reproduction of any
portion of this manual is prohibited. The material in this manual is for information purpose
only. It is subject to change without notice. Software House assume no responsibility for
incorrect information this manual may contain.
© 2015 Tyco Security Products.
MI rights reserved.
EFTA01224571
Table of Contents
Preface
Finding More Information ii
Conventions iii
Software House Customer Support Center iv
Chapter 1 - Introduction 1
Overview 2
Chapter 2 - Video Server 3
Creating a Video Folder 4
VideoEdge Server Editor 5
Accessing the VideoEdge Server Editor 6
VideoEdge Server General Tab 7
Creating a VideoEdge Server 10
Configuring a VideoEdge Server 10
Editing a VideoEdge Server Configuration 11
Deleting a VideoEdge Server 12
VideoEdge Server Alarms Tab 13
VideoEdge Server Alarms Tab Definitions 14
Alarm Tab Tasks 15
Configuring an Alarm to Activate an Event 16
Configuring Video Camera Action 16
C•CURE 9000 VideoEdge Configuration Gukie 3
EFTA01224572
Removing an Alarm 17
Alarm Configuration Example 17
VideoEdge Server State Images Tab 18
State Image Tab Tasks 19
Changing the VideoEdge Server State Image 19
Restoring the VideoEdge Server State Image to the Default Image 20
Chapter 3 - VideoEdge Camera 21
VideoEdge Camera Editor 22
Accessing the VideoEdge Camera Editor 22
VideoEdge Camera General Tab 24
VideoEdge Video Camera General Tab Definitions 24
Preset Controls 25
Pattern Controls 26
Configuring a VideoEdge Camera 27
Creating a VideoEdge Camera Template 28
Importing a VideoEdge Camera 28
Viewing a List of VideoEdge Cameras 29
Deleting a VideoEdge Camera 29
Modifying a VideoEdge Camera 30
VideoEdge Camera Alarms Tab 31
VideoEdge Camera Alarms Tab Definitions 31
VideoEdge Camera Alarm Configuration Example 33
Configuring a Video Camera Alarm 34
Removing A Video Alarm 35
VideoEdge Camera State Images Tab 36
Changing the VideoEdge Camera State Image 37
Restoring the VideoEdge Camera State Image to the Default Image 37
VideoEdge Camera Viewer 39
Retrieving a Recorded Video 40
Exporting a Video 41
VideoEdge Playback Controls 43
Instant Playback Controls 43
Playback Controls Available While Viewing Recorded Video 45
4 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224573
Chapter 4 - Video View 47
Video View Editor 48
Accessing the Video View Editor 49
Creating a Video View 50
Configuring a Video View 50
Deleting a Camera from the View 51
Deleting a Video View 51
Chapter 5 - Video Tour 53
Video Tour Overview 54
Accessing the Video Tour Editor 55
Creating a Video Tour 55
Configuring a Video Tour 55
Deleting a Video Tour 56
VideoEdge Video Tour General Tab 57
VideoEdge Video Tour General Tab Definitions 57
Video Tour Preview Window 57
Chapter 6 - Journal Messages 59
Journal Message Definitions 60
C•CURE 9000 1ndeoEdge Configuration Gukie 5
EFTA01224574
6 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224575
Preface
The C•CURE 9000 VideoEdge Configuration Guide is for new and experienced security system users
who want to learn to use this product with the Security Management System.
In this preface
Finding More Information ii
Conventions iii
Software House Customer Support Center iv
C•CURE 9000 VideoEdge Configuration Guide Preface
EFTA01224576
Finding More Information
Finding More Information
You can access C•CURE 9000 manuals and online Help for more information about C•CURE 9000.
Manuals
C•CURE 9000 software manuals are available in Adobe PDF format on the C•CURE 9000 DVD.
You can access the manuals if you copy the appropriate PDF files from the C•CURE 9000
Installation DVD English \ Manuals folder.
The available C•CURE 9000 and Software House manuals are listed in the C•CURE 9000 Installation
and Upgrade Guide, and appear as hyperlinks in the online.pdf file on the C•CURE 9000 DVD
English \ Manuals folder.
These manuals are also available from the Software House Member Center website
Online Help
You can access C•CURE 9000 Help by pressing Fl or clicking Help from the menu bar in the
Administration/Monitoring Station applications.
ii Preface C•CURE 9000 VideoEdge Configuration Guide
EFTA01224577
Conventions
Conventions
This manual uses the f >Bowing text formats and symbols.
Convention Meaning
Bold This font indicates screen elements, and also indicates when you should take a direct action in a
procedure.
Bold font describes one of the following items:
• A command or character to type, or
• A button or option on the screen to press, or
• A key on the keyboard to press
• A screen element or name
blue color text Indicates a hyperlink to a UR L. or a cross-reference to a figure, table, or section in this g uide.
Regular italic font Indicates a new term.
<te)d> Indicates a variable.
The following items are used to indicate important information.
Indicates a note. Notes call attention to any item of information that may be of special
NOTE importance.
Indicates an alternate method of performing a task.
TIP
Indicates a caution. A caution contains information essential to avoid damage to the
system. A caution can pertain to hardware or software.
Indicates a warning. A warning contains information that advises users that failure
to avoid a specific action could result in physical harm to the user or to the
hardware.
STOP Indicates a danger. A danger contains information that users must know to avoid
death or serious injury.
C•CURE 9000 IlideoEdge Configuration Guide Preface III
EFTA01224578
Software House Customer Support Center
Software House Customer Support Center
Telephone Technical Support
During the period of the Agreement, the following guidelines apply:
■ Software House accepts service calls only from employee of the Systems Integrator of Record for
the installation associated with the support inquiry.
Before Calling
Ensure that you:
■ Are the Dealer of record for this account.
■ Are certified by Software House for this product.
■ Have a valid license and current Software Support Agreement (SSA) for the system.
■ Have your system serial number available.
■ Have your certification number available.
Hours Normal Support Hours Monday through Friday, 8:00 to 8:00 , EST. Except
holidays.
Emergency Support Hours 24 hourstday, seven days a week, 365 daystyear.
Requires Enhanced SSA"7 x 24- Standby Telephone
Support
(emergency) provided to Certified Technicians.
For atl other customers. billable on time and materials basis.
Minimum charges apply- See NISRP.
Phone For telephone support contact numbers focalregions, see
suppoitaspx.
Iv Prolate C•CURE 9000 VldeoEdge Configuration Guide
EFTA01224579
Introduction
'Ibis chapter introduces VideoEdge.
In this chapter:
Overview
C•CURE 9000 VideoEdge Configuration Guide Chapter 1
EFTA01224580
Overview
Overview
The VideoEdge integration allows configuration of VideoEdge video servers and video cameras
within the C•CURE 9000. The operator can display video views, video tours, perform PTZ controls
and trigger alarm events or camera actions when the camera alarm is activated.
The following is a list of major features supported by this integration:
■ Live video
■ Simultaneous live and recorded video views from up to 16 cameras
■ Up to four live video camera windows based on events
■ Video Export
■ Playback of pre-recorded video
■ Video control such as PTZ (domes only)
■ Audio control
■ Video views
■ Video tours
■ Video alarms
■ PTZ presets based on events, alarm inputs or video tours
2 Chapter 1 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224581
2
Video Server
This chapter describes how to configure a VideoEdge Server.
In this chapter
Creating a Video Folder 4
VideoEdge Server Editor 5
Accessing the VideoEdge Server Editor 6
VideoEdge Server General Tab 7
VideoEdge Server Alarms Tab 13
VideoEdge Server State Images Tab 18
C•CURE 9000 IfideoEdge Configuration Guide Chapter 2 3
EFTA01224582
Creating a Video Folder
Creating a Video Folder
You create video folders from the Video Pane to store video objects such as IP Cameras, Video
Servers, Video Tours and Video Views.
To Create a Video Folder
1. In the Navigation Pane of the Administration Workstation, click Video to open the Video pane.
2. Right-click on the Video folder at the top of the bee and select Video Folder>New from the
context menu. The Video Folder Editor opens and you can configure the video folder.
3. Enter a name and description (optional) for the folder.
4. To save your new video folder, click Save and Close.
Alternatively, if you want to save the video folder and then create a new one, click Save and
New.
The current video folder is saved and closed, but the Video Folder Editor remains open to allow
you to create a new video folder.
4 Chapter 2 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224583
VideoEdge Server Editor
VideoEdge Server Editor
The VideoEdge Server Editor lets associate video server objects with camera, alarm, and server
action objects.
The Video Server Editor contains three configuration tabs. Click on the following tabs for
descriptions of their fields and buttons:
■ VideoEdge Server General Tab on Page 7
■ VideoEdge Server Alarms Tab on Page 13
■ VideoEdge Server State Images Tab on Page 18
See the following tasks:
■ Accessing the VideoEdge Server Editor on Page 6
■ Creating a VideoEdge Server on Page 10
■ Configuring a VideoEdge Server on Page 10
■ Editing a VideoEdge Server Configuration on Page 11
■ Deleting a VideoEdge Server on Page 12
■ Configuring an Alarm to Activate an Event on Page 16
■ Configuring Video Camera Action on Page 16
■ Removing an Alarm on Page 17
■ Changing the VideoEdge Server State Image on Page 19
■ Restoring the VideoEdge Server State Image to the Default Image on Page 20
C•CURE 9000 MaoEdge Configuration Guide Chapter 2 5
EFTA01224584
Accessing the WleoEdge Server Editor
Accessing the VideoEdge Server Editor
To Access the VideoEdge Server Editor in the Video Tree
1. In the Navigation pane of the C•CURE 9000 Administration Workstation, click Video. The
Video pane opens.
2. Click t I to expand the Video tree.
3. Right-click on the Video folder you created, and select VideoEdge 4.0 Server>New.
The VideoEdge Server Editor opens. For more information about server configuration, see
Configuring a VideoEdge Server on Page 10.
To Access the VideoEdge Server Editor in the Dynamic View
1. In the Navigation pane of the Administration Workstation, click Video to open the Video pane.
2. Click the Video drop-down menu and select VideoEdge 4.0 Server.
3. Click la to open a Dynamic View showing all VideoEdge Servers.
4. Double-click on a VideoEdge Server. The VideoEdge 4.0 Server editor opens. For information
about server configuration, see Configuring a VideoEdge Server on Page 10.
6 Chapter 2 C•CURE 9000 IndooEdge Configuration Guide
EFTA01224585
VideoEdge Server GeneralTab
VideoEdge Server General Tab
The VideoEdge Server 4.0 General tab, shown in Figure 1 on Page 7, lets you configure the
VideoEdge Server basic information, check the video server connection, and open a VideoEdge Web
Page.
Table 1 on Page 8 describes the Video Server General Tab fields and buttons.
Figure 1: VideoEdge Server General Tab
Sin al Clort leslee
keoEct..1
berrobta
r fee!
Gem,' I Uwar 0•fred Adds I renal St*• 0•490s
Sena ID
Video Nand. Md./cage 4 0
Tenejone
=LI
Seam II*
Connieabes Pen on-
in Vase Pen f
&we Port ss'..cto I
Ens Banat
0NALDen Ccalgurolon
PAC4rePs
Secure Car/tar r
TCPI/ose r
Ever/hob:alit
PO Nei Ta
11 SOCCIO Corm DJ Um. weak
r I
r 1—E
C•CURE 9000 VideoEdge Configuration Guide Chapter 2 7
EFTA01224586
VideoEdge Server General Tab
Table 1: VdeoEdge Server General Ta b Definitions
Field & Description
Buttons
Name Enter a unique name up to 100 characters long to identify the server.
Description Enter a textual description up to 500 characters for the server.
Enabled If enabled. C•CURE 9000 attempts to communicate with the server. If not enabled C•CURE 9000 does
not attempt to communicate with the server.
Server ID
Video Protocol Automatically populated with the video protocol: VideoEdge 4.0
Time zone The Time Zone field is optional for VideoEdge. You can enter the Time Zone for the NVR for
informational purposes such as viewing what time zone the server is in via the Dynamic View.
Import Cameras Imports all camera configuration information to the video server.
Connect Checks the server connection. If all user cxedentials are entered and validated, the server isonline.
Online After the connection is successfully estabbshed, indicates if the current video server is online.
Server Info
Communication Displays the communication port number previously configured for remote communication in the
Port VideoEdge 4.X Sewer. The defautt is 80.
If Secure Connection is enabled, then the Communication Port must be changed to match the Secure
HTTPS Port on the VideoEdge NVR Web GUI to allow for a secure connection.
The default port used for secure HTTPS is 443.
Live Video Port Displays the port number previoustyconfigured for We video in the VideoEdge Server. The default value
is 554.This field can be edited.
Alarm Port Displays the port number previoustyconfigured for the alarm trigger in the VideoEdge Serval'. The
default value is 5003.This field is read only.
Open NVR Open the VideoEdge Web page to configure the VideoEdge NVR.
Configuration
Domain Not applicable for VideoEdge.
8 Chapter 2 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224587
VideoEdge Server General Tab
Table 1: VideoEdge Server General Tab Definitions (continued)
Field & Description
Buttons
User Name Enter the user name used to log into the VideoEdge Server.
Password Enter the password used to log into the VideoEdge Server.
Re-enter Re-enter the password.
Password
IP Address Enter the IP address for the specified video server.
Secure If enabled (checked), then all VideoEdge communication from the C•CURE 9000 to the NVR will be
Connection transmitted over HTTPS instead of HTTP.
If Secure Connection is enabled, then the Communication Port must be changed to match the Secure
HTTPS Port on the VideoEdge NVR Web GUI to allow for a secure connection.
When the configuration is saved, the SSL Certificate is is requested from the VideoEdge NVR for
permission to store the certificate on the C•CURE 9000 system. See the NVR Guide for more
information about creating and installing certificates.
TCP Mode If enabled (checked). then a II VideoEdge communications connect to VideoEdge NVR over TCP. This
provides a more reliable connection in low bandwidth environments, or when connecting to the
VideoEdge NVR over a WAN.
Event Action Info
Poll Period Indicates how often you want the video server polled for status information.
The range is0 to 999. The default is 100 seconds.
Comm Fad Delay Not applicable for VideoEdge.
Pre-second frame Not applicable for VideoEdge.
rate to use during
recording
Time Sync at Not applicable for VrdeoEdge .
hh:MM:SS
C•CURE 9000 VideoEdge Configuration Guide Chapter 2 9
EFTA01224588
VdeoEdge Server General Tab
Creating a VideoEdge Server
To Create a VideoEdge Server
1. In the Navigation pane of the C•CURE 9000 Administration Workstation, click Video to open
the Video pane.
2. Right-click on the Video folder at the top of the tree and select Video Folder>New from the
context menu. The Video Folder Editor opens and you can configure the video folder.
3. Enter a name and description (optional) for the folder.
4. To save your new video folder, click Save and Close.
Alternatively, if you want to save the Video server and then create a new one, click Save and
New.
The current Video Server is saved and closed, but the Video Server Editor remains open to allow
you create a new Video Server.
Configuring a VideoEdge Server
To Configure a VideoEdge Server
1. Create a new VideoEdge Server, or open an existing one with the General tab available. See also
Accessing the VideoEdge Server Editor on Page 6 and Editing a VideoEdge Server Configuration
on Page 11.
2. Enter a unique name up to 100 characters long in the Name field.
3. Enter a textual description (optional) up to 500 characters for the VideoEdge Server in the
Description field.
4. Click the Enabled option to establish communication between C•CURE 9000 and the VideoEdge
Server.
5. Create a basic configuration in General tab. See VideoEdge Server General Tab on Page 7.
6. Click the Alarms tab to configure alarm for the VideoEdge Server. See VideoEdge Server Alarms
Tab on Page 13
10 Chapter 2 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224589
VideoEdge Server General Tab
7. Click the State Images tab to view the state images for the VideoEdge Server. See VideoEdge
Server State Images Tab on Page 18
8. Click Save and Close to save the configuration and exit.
Editing a VideoEdge Server Configuration
To Edit a VideoEdge Server Configuration on the Video Tree
1. In the Navigation Pane of the C•CURE 9000 Administration Workstation, click Video to open the
Video pane.
2. Expand the Video tree. Open the Video folder by clicking .0 l to the left of the folder.
3. Right-click on the VideoEdge Server that you want to edit and select Edit from the context menu.
The VideoEdge 4.0 Server Editor opens with the General tab available.
You can also open a VideoEdge Server by double-clicking on its name in the Video tree.
To Edit a VideoEdge Server Configuration in the Dynamic View
1. In the Navigation Pane of the C•CURE 9000 Administration Workstation, click Video to open the
Video pane.
2. Select VideoEdge 4.0 Server from the Video pane drop-down list.
3. Expand the Video tree. Click _I I to open the video folder you created.
4. Right-click on the VideoEdge Server in the list that you want to edit and select Edit from the
context menu.
The VideoEdge 4.0 Server Editor opens with the General tab available.
You can also open a VideoEdge Server by double-clicking on its name in the Dynamic View.
C•CURE 9000 VideoEdge Configuration Guide Chapter 2 11
EFTA01224590
VdeoEdge Server General Tab
Deleting a VideoEdge Server
To Delete a VideoEdge Server on the Video Tree
1. In the Navigation pane of the C•CURE 9000 Administration Station, click Video to open the
Video pane.
2. Expand the Video tree. Open the Video folder by clicking t• I to the left of the folder.
3. Right-click on the VideoEdge Server that you want to delete, select Delete from the context
menu.
A message box appears stating "Are you sure that you want to delete the selected VideoEdge 4.0
Server object?"
4. Click Yes to delete the VideoEdge Server.
To Delete a VideoEdge Server in Dynamic View
1. In the Navigation pane of the Administration Station, click Video to open the Video pane.
2. Select VideoEdge from the Hardware pane drop-down list.
3. Click in to open a Dynamic View showing all VideoEdge Server objects.
4. In the list, right-click the VideoEdge Server that you want to delete and select Delete from the
context menu.
A message box appears stating "Are you sure that you want to delete the selected VideoEdge 4.0
Server object?"
5. Click Yes in the message box to delete the VideoEdge Server.
12 Chapter 2 C•CURE 9000 IndooEdge Configuration Guide
EFTA01224591
VdeoEdge Server Alarms Tab
VideoEdge Server Alarms Tab
The VideoEdge Server Alarms tab, shown in Figure 2 on Page 13, provides a list of alarms you have
configured for this video server. You must set up server alarms using the vendor utility on the video
server side before the alarms can work in C•CURE 9000.
This section contains the following information:
■ VideoEdge Server Alarms Tab Definitions on Page 14
■ Alarm Tab Tasks on Page 15
■ Mann Configuration Example on Page 17
Figure 2: VdeoEdge 4.0 Sarver Alarms Tab
livitirobir 4.0 serve. VMrrtdr I
Srm a-d Cox 'a • Jam enclPist
Nee I.,drorer:
Desaohn
Enal*4 Faun Dela
ewes N•ms I Stale mget
era* Vas Actca es* j smear
C•CURE 9000 VideoEdge Configuration Guide Chapter 2 13
EFTA01224592
VideoEdge Server Alarms Tab
VideoEdge Server Alarms Tab Definitions
Table 2 on Page 14describes the fields and buttons on the VideoEdge 4.0 Server Alarms tab.
Table 2: VideoEdge 4.0 Server Alarms Tab Definitions
Field Description
Add C lick Add in the Alarms tab to create a new alarm.
Remove Click Remove in the Alarms tab to delete a selected alarm.
Property Click in the Property column. and then click ••• . The Property browser opens a list of predefined
properties available for the server. Click a Property to select it and add it to the column.
VideoEdgecurrenttyonty supports Video Server Alarm.
Value Click in the Value column to display a drop-down list of Values associated with the Property that was
selected. Click on the Value you want to include as a parameter for the trigger to assign it to the Video
Server Alarm.
If you select the propertyof Video Server Alarm. click within the Value column to display a drop-down list
with two values available for you to select: Online or Offline.
NOTE: You must select the Property before you can select the Value.
Action Click in the Action column to display a drop-down list of valid actions. Click on the Action that you want to
include as a parameter for the trigger to assign it to the Video Server. Two types of actions are available:
Activate Event and Video Camera Action.
• If you select Activate Event, the lower pane in the Alarm tab displays an Event field for you to define
the Action details. See Configuring an Alarm to Activate an Event on Page 16
• If you select Video Camera Action, the lower pane displays hvo sub-tabs: Camera tab and Action
Type tab. See Configuring Video Camera Action on Page 16.
Details Displaysdetails about how the Action was configured.
Schedule Only the Always schedule is available for VideoEdge Server.
Event Albws you select an event for the alarm.
NOTE: Event is available onty if Activated an Event was selected in the Action column drop-down list.
See the C•CURE 9000 Software Configuration Guide for information about events.
14 Chapter 2 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224593
VideoEdge Server Alarms Tab
Table 2: VideoEdge 4.0 Server Alarms Tab Definitions (continued)
Field Description
Camera tab (available if Video Camera Action was selected in the Action field)
Server
Specify the server for the action. Click Q to open a list of predefined video servers.
NOTE: You must select the server before you can select the camera.
Camera Specify the camera for the action. Click 0 to open a list of predefined video cameras.
Action Type tab (available if Video Camera Action was selected)
Action Type Select the action type.
NOTE: Only Camera Preset Command and Camera Pattern Command are supported.
Enter the parameters for the action type. The parameters vary according to the action type selected. See
Parameterson Page 15.
Parameters
Pre Alarm Time Set pre-alarm recording time for the camera when you select Record Camera as the action type.
Post Alarm Time Set post-alarm recording time for the camera when you select Record Camera as the action type.
Preset Select the preset number to set this preset as the object when you select Camera Preset Command as
the action type.
Pattern Select the pattern number to set this pattern as the object when you select Camera Pattern Command as
the action type.
Schedule Only the Always Schedule is available for VideoEdge Server.
Alarm Tab Tasks
The following tasks are performed in the Alarms tab:
■ Configuring an Alarm to Activate an Event on Page 16
■ Configuring Video Camera Action on Page 16
■ Removing an Alarm on Page 17
C•CURE 9000 VideoEdge Configuration Guide Chapter 2 15
EFTA01224594
VdeoEdge Server Alarms Tab
Configuring an Alarm to Activate an Event
To Configure an Alarm to Activate an Event
1. From the VideoEdge Server Editor dialog box, navigate to the Alarms tab.
2. Click Add to create a new alarm. An empty row is added to the table.
3. Click in the Property column, and then click on 0. The selection dialog box opens.
4. Click on Video Server Alarm to select it.
5. Click in the Value column, and select Offline or Online from the drop-down menu.
6. Click in the Action column, and select Activate an Event.
The lower pane in the Alarm tab displays an Event field for you to define the Action details.
7. Click CI to open the Event selection dialog box. Select an event that you want to associate with
the alarm. See the C•CURE 9000 Software Corifiguration Guide for information about configuring
Events.
The Details column displays the event selected.
8. Click Save and Close to save the configuration and exit.
Configuring Video Camera Action
To Configure Video Camera Action
1. From the VideoEdge Server Editor dialog box, click on the Alarms tab.
2. Click Add to create a new alarm. An empty row is added to the table.
3. Click in the Property column, then click on Q. The selection dialog box opens.
4. Click on Video Server Alarm to select it.
5. Click in the Value column, and select Offline or Online from the drop-down menu.
6. Click in the Action column, and select Video Camera Action.
The lower pane in the Alarms tab displays two sub-tabs: Camera and Action Type.
18 Chapter 2 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224595
VIdeoEdge Server Alamis Tab
7. Click on the Camera tab.
8. Click on Q to select a server and then a camera.
9. Click on the Action Type sub-tab, and select an action type.
Depending on the action type selected, other options will appear under the Action Type field.
10. Click Save and Close to save the configuration and exit.
Removing an Alarm
To Remove an Alarm
1. From the VideoEdge Server Editor dialog box, click on the Alarms tab.
2. Click on the row of the alarm you want to remove to select it.
3. Click Remove.
4. Click Save and Close to save the configuration and exit.
Alarm Configuration Example
Table 3 on Page 17 provides an example of an alarm configuration.For information about how to
create and configure an event, see the C•CURE 9000 Software Configuration Guide.
Table 3: Alarm Configuration Example
The following Alarms tab settings:
Property Value Action Details Schedule
Video Server Alarm Online Activate Event Display_1 Always
Would create the fo lowing Event:
Anytime (Always Schedule) the Video Server Alarm (Property) equals Online (Value), activate the event
(Action) named Display_i (Details).
Display_l is an event you select in the Event field (a pre-configured event).
C•CURE 9000 videoEdge Conflgutation Guide Chapter 2 17
EFTA01224596
VideoEdge Server State Images Tab
VideoEdge Server State Images Tab
The State Images tab, shown in Figure 3 on Page 18, allows you to change the default images used
to indicate the VideoEdge Server state on the Monitoring Station.
Table 4 on Page 19 lists the state and description of the VideoEdge Server State Images icons.
Flgu re 3: Video Server State Images Tab
Nara Nil
P Eratixl PolkaDitel
Gonad Aims bib mos l
Smr Its
18 Chapter 2 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224597
VdeoEdge Server State Images Tab
Table 4: VdeoEdge Server State Images Icons
ICON State Description
Unknown The video server is in an unknown state.
Online The video server isonline.
Ls
r2....._
-- Offline The video server is offtine.
vitl."
State Image Tab Tasks
State Images Tab Tasks
The following tasks are performed in the VideoEdge Server State Images tab:
• Changing the VideoEdge Server State Image on Page 19
• Restoring the VideoEdge Server State Image to the Default Image on Page 20
Changing the VideoEdge Server State Image
To Change the VideoEdge Server State Image
I . From the VideoEdge Server State Images tab, double-click the existing image. A Windows Open
dialog box appears allowing you to browse for a folder in which you have placed replacement
images.
2. When you locate the replacement image, select it and click Open to replace the default image
with this image.
3. Click Save and Close to save the configuration.
C•CURE 9000 VideoEdge Configuration Guide Chapter 2 19
EFTA01224598
VideoEdge Server State Images Tab
Restoring the VideoEdge Server State Image to the Default Image
To Restore the VideoEdge Server State Image Back to the Default
1. In the State Images tab, right-click on the image and select Restore Default.
2. Click Save and Close to save the server configuration.
20 Chapter 2 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224599
3
VideoEdge Camera
This chapter describes how to configure a VideoEdge Camera.
In this chapter:
VideoEdge Camera Editor 22
VideoEdge Camera General Tab 24
VideoEdge Camera Alarms Tab 31
VideoEdge Camera State Images Tab 36
VideoEdge Camera Viewer 39
VideoEdge Playback Controls 43
C•CURE 9000 VideoEdge Configuration Guide Chapter 3 21
EFTA01224600
VideoEdge Camera Editor
VideoEdge Camera Editor
The VideoEdge Camera Editor lets you associate the VideoEdge Camera with camera alarms and
camera action objects.
The VideoEdge Camera Editor contains three configuration tabs. Click on the following tabs for
descriptions of their fields and buttons:
• VideoEdge Server General Tab on Page 7
■ VideoEdge Camera Alarms Tab on Page 31
■ VideoEdge Camera State Images Tab on Page 36
See the following tasks:
■ Configuring a VideoEdge Camera on Page 27
■ Creating a VideoEdge Camera Template on Page 28
■ Importing a VideoEdge Camera on Page 28
■ Viewing a List of VideoEdge Cameras on Page 29
■ Modifying a VideoEdge Camera on Page 30
■ Configuring a Video Camera Alarm on Page 34
■ Removing A Video Alarm on Page 35
■ Changing the VideoEdge Camera State Image on Page 37
■ Restoring the VideoEdge Camera State Image to the Default Image on Page 37
Accessing the VideoEdge Camera Editor
To Access the VideoEdge Camera Editor in the Video Tree
1. In the Navigation pane of the C•CURE 9000 Administration Workstation, click Video. The
Video pane opens.
2. Click _r I to expand the Video tree.
3. Go to the video folder where the server and camera are located.
22 Chapter 3 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224601
VideoEdge Camera Editor
4. Right-click on the camera and select Edit. The VideoEdge 4.0 Camera Editor opens with the
General tab displayed, as shown in Figure 4 on Page 24Figure 4 on Page 24
To Access the VideoEdge Camera Editor in the Dynamic View
1. In the Navigation pane of the Administration Workstation, click Video to open the Video pane.
2. Click the Video drop-down menu and select VideoEdge 4.0 Camera.
3. Click la to open a Dynamic View showing all camera objects.
4. Select the camera, right-click on it and select Edit. The VideoEdge 4.0 Camera Editor opens with
the General tab displayed, as shown in Figure 4 on Page 24.
C•CURE 9000 VldeoEdge Configuration Guide Chapter 3 23
EFTA01224602
VideoEdge Camera General Tab
VideoEdge Camera General Tab
The VideoEdge 4.0 Camera General tab, shown in Figure 4 on Page 24, lets you create basic settings
for cameras.
Figure 4: VideoEdge 4.0 Video Camera General Tab
k, ilidecEdge4.0 Camera - CameraS
Save end Clo:e 7 Save end Nev
tin. e,-eras
anCoDOC0
General [Pkau• I Stele ewes
Comet a boe
Hot.
VideoEdge Video Camera General Tab Definitions
Table 5 on Page 25 describes the General tab fields and buttons. The fields and buttons available
depend on the camera type.
24 Chapter 3 C•CURE 9000 WdooEdge Configuration Guide
EFTA01224603
VideoEdge Camera General Tab
Table 5: VideoEdge 4.0 Camera General Ta b Definitions
Field/Button Description
Name Enter a unique name up to 100 characters long for the VdeoEdge Video Camera.
Description Enter a general description. up to 500 characters long for the camera.
Enabled Select the Enabled option to establish the momunication between the video camera and C•CURE 9000.
Camera Type Select the camera type from the drop-down list. Two types are available: Fixed and Dome.
Number The unique sequence number used to dentify the camera. Once you enter a number. Ise video from that
camera is displayed on the video control. The default is 0.
Dome Controls
Pan/Tilt Focus Near Sequence
Zoom In
" [2] Close
-..
Iris Open
L
0 6 b Flip
0
Iris Close— 4 P' Pattern
NN
Zoom Out Focus Far Preset
NOTE:According to the type of dome and recorder being used, the controls available mayvary.
Preset Controls
Click LI to open the preset control:
C•CURE 9000 VideoEdge Configuration Guide Chaptur 3 25
EFTA01224604
VdeoEdge Camera General Tab
■ To create a new preset, select a preset position by using Pan/Tilt control, then open the preset
control and click
list.
n. The new preset number is automatically added in the preset drop-down
■ To delete an existing preset, select the preset from the preset drop-down list and click i.
■ To go to one specific preset, select the preset from the preset drop-down list and click 101.
■ To set one specific preset, select a preset position by using Pan/Tilt control, then open the preset
control, select the preset from the preset drop-down list and click .
Pattern Controls
Click S to open pattern control:
■ To create a new pattern, click
pattern drop-down list.
n. The new pattern number is automatically added in the
■ To delete an existing pattern, select the pattern from the pattern drop-down list and click M.
■ To go to one specific pattern, select the pattern from the pattern drop-down list and click la .
■ To set one specific pattern, select the pattern from the pattern drop-down list and click to
open the pattern recording control:
■ Select a position where the pattern will start, then click sto begin recording. Then do
operations that this pattern should perform.
■ Click NJ to end recording.
26 Chapter 3 C•CURE 9000 VldeoEdge Configuration Guide
EFTA01224605
VdeoEdge Camera General Tab
Configuring a VideoEdge Camera
To Configure a VideoEdge Camera
1. In the Navigation Pane of the C•CURE 9000 Administration Workstation, click Video to open the
Video pane.
2. Click on Video in the Video Tree to expand the tree.
3. Click on the video folder where the VideoEdge server is located.
4. Right-click on the VideoEdge Server and select VideoEdge 4.0 Camera -> New.
The VideoEdge 4.0 Camera Editor opens with the General tab displayed, as shown in Figure 4
on Page 24.
5. Enter a unique name up to 100 characters in the Name field.
6. Enter a textual description up to 500 characters in the Description field.
7. Click in the Enabled check box to establish communication between C•CURE 9000 and the
VideoEdge camera.
8. You can click the Alarms tab to configure Alarms for the VideoEdge camera. See VideoEdge
Camera Alarms Tab on Page 31
9. You can click the State Images tab to view the state images for VideoEdge camera. See
VideoEdge Camera State Images Tab on Page 36.
10. To save the video camera configuration, click Save and Close.
Alternatively, if you want to save the camera and then create a new one, click Save and New.
The current video camera is saved and closed, but the VideoEdge Camera Editor remains open
to allow you create a new video camera.
When the VideoEdge Server changes from offline to online, if the camera index in
NOTE
C•CURE 9000 does not exist on the VideoEdge Server, the camera is deleted
automatically.
C•CURE 9000 VideoEdge Configuration Guide Chapter 3 27
EFTA01224606
VdeoEdge Camera General Tab
Creating a VideoEdge Camera Template
To Create a VideoEdge Camera Template
1. In the Navigation Pane of the Administration Workstation, click Video to open the Video
pane.
2. Click on Video in the Video Tree to expand the tree.
3. Click on the video folder where the VideoEdge server for which you want to create the camera
template is located.
4. Right-click on the server, and select VideoEdge 4.0 Camera Camera>New Template from the
context menu. The VideoEdge 4.0 Camera (Template) opens for you to configure the template.
5. To save your new Video Camera Template, click Save and Close. The saved Video
Camera template appears under New Template on the context menu.
Importing a VideoEdge Camera
To Import a VideoEdge Camera
1. In the Navigation Pane of the C•CURE 9000 Administration Workstation, click Video to open the
Video pane.
2. Click on Video in the Video Tree to expand the tree.
3. Click on the video folder where the VideoEdge server for which you want to import the camera
is located.
4. Right-click on the VideoEdge Server and select Edit The VideoEdge Server Editor opens with
the General tab available.
5. In the General tab, click the Import Cameras button to import cameras set up for the video
server.
"The camera import is complete" message appears after the import is complete.
6. Click OK.
7. Click Save and Close to save the configuration and exit.
28 Chapter 3 C•CURE 9000 IndooEdge Configuration Guide
EFTA01224607
VideoEdge Camera General Tab
The imported cameras are listed in the video folder under the VideoEdge server you selected to
import the camera
Sometimes you will see the camera name similar to ( cameraname_(n)). This happens
NOTE
in the following situation.
The VideoEdge Server in C•CURE 9000 has a camera named "FrontDoor". A video
camera named FrontDoor" is added to the VideoEdge Server on the Web page. Then,
the newly added camera is added automatically in C•CURE 9000 with a new name
of "FrontDoor_(n)". Here ri starts at 2. If the new name (FrontDoor_00) is also same as
the existing one, it is renamed as (FrontDoor_(n+1)) until the name is unique.
Viewing a List of VideoEdge Cameras
To View a List of VideoEdge Cameras
1. In the Navigation Pane of the Administration Workstation, click Video to open the Video pane.
2. Click on the Video drop-down list and select VideoEdge 4.0 Camera.
3. Click 0 to open a Dynamic View showing all VideoEdge cameras.
Deleting a VideoEdge Camera
This section describes how to delete a video camera from the Video Tree and from the Dynamic
View.
To Delete a VideoEdge Camera in the Video Tree
1. In the Navigation pane of the C•CURE 9000 Administration Workstation, click Video to open
the Video pane.
2. Click Video in the Video Tree.
3. Go to the video folder where the VideoEdge server and the camera are located.
4. Right-click on the camera and select Delete from the context menu.
A message box appears stating "Are you sure that you want to delete the selected VideoEdge 4.0
Camera object?"
C•CURE 9000 VideoEdge Configuration Guide Chapter 3 29
EFTA01224608
VideoEdge Camera General Tab
5. Click Yes to delete the VideoEdge camera.
To Delete a VideoEdge Camera in the Dynamic View
1. In the Navigation pane of the Administration Workstation, click Video to open the Video pane.
2. Click Video in the Video Tree.
3. Click on the Video drop-down menu and select VideoEdge 4.0 Camera.
4. Click to open a Dynamic View showing all camera objects.
5. Select the camera, right-click on it and select Delete from the context menu.
A message box appears stating "Are you sure that you want to delete the selected VideoEdge 4.0
Camera object?"
6. Click Yes to delete the VideoEdge Camera.
Modifying a VideoEdge Camera
To Edit a VideoEdge Camera in the Video Tree
1. In the Navigation pane of the Administration Workstation, click Video to open the Video pane.
2. Click Video in the Video Tree to view the folders.
3. Go to the video folder where the camera is located.
4. Right-click on the camera and select Edit from the context menu.The VideoEdge 4.0 Camera
Editor opens.
To Edit a Video Camera in the Dynamic View
1. In the Navigation pane of the Administration Workstation, click Video to open the Video pane.
2. Click Video in the Video Tree.
3. Click on the Video drop-down menu and select VideoEdge 4.0 Camera.
4. Click El to open a Dynamic View showing all camera objects.
5. Select the camera, right-click on it and select Edit from the context menu. The VideoEdge 4.0
Camera Editor opens.
30 Chapter 3 C•CURE 9000 VldeoEdge Configuration Guide
EFTA01224609
VdeoEdge Camera Alarms Tab
VideoEdge Camera Alarms Tab
The VideoEdge 4.0 Camera Alarms tab, shown in Figure 5 on Page 31, provides a list of alarms
configured for the video camera. You must set up camera alarms using the vendor utility on the
video server side before the alarms can work in C•CURE 9000.
Figure 5: VideoEdge 4.0 Camera Alarms Tab
Viderralge4.0 Carnes - Cone 'IMMENSE,
14 Save and Close Save and New
!tame Ca-era5
&Knew
II Enabled
Crencral Neml 9Aresna9051
eel Add P. Remove
Prepare Vela Aebtel Deals Stet
l VdeoCameta Ain I Hamel I"lavabo Event I. 'Nam
VideoEdge Camera Alarms Tab Definitions
Table 6 on Page 32 provides definitions for the fields on VideoEdge 4.0 Camera Alarms tab.
C•CURE 9000 VldeoEdge Configuration Guide Chapter 3 31
EFTA01224610
VideoEdge Camera Alarms Tab
Table 6: VdeoEdge 4.0 Camera Alarm Tab Definitions
Field Description
Add Adds an aLa rm to the video camera.
Remove Removes an alarm from the video camera.
Property Click in the Property column. and then click ... . The Property browser opens with a fist of properties
available for the panel. Click a Property to select it and add it to the column.
Available properties are listed below:
• Dry Contact
• User Alarm
• Video Camera Alarm
• Videoloss.
Value NOTE: You must select the Property before you can select the Value.
Click in the Value column to display a drop-down list of Values associated with the Property that you have
selected. Click a Value you want to include as a parameter for the trigger to assign it to the camera.
• If you select the property of Dry Contact User Alarm. or Videoloss, two values are available: True
and False. To enable the value of True. select the check box that appears when you dick in the field.
To change the value to False. clear the check box.
• If you select the property of Video Camera Alarm. click in the Value column to display a drop-down
list with four values available for you to select: Normal. Motion. Analytic and Alarm.
Action Click in the action Action column to display a drop-down list of valid actions. Click on the action that you
want to include as a parameter for the trigger to add it. Two types of actions are available now: Activate
Event and Video Camera Action.
• For more information on Activate Event. see Configuring an Alarm to Activate an Event on Page 16
• For more information on Video Camera Action. see tonfiguring Video Camera Action on Page 16
Details Displays dela ils about how the Action was configured.
Schedule Only the Always Schedule is available for VideoEdge Video Camera.
Event Mows you select an event for the alarm.
NOTE: Event isavailableonly if Activated an Event was selected in the Action column drop-down list.
See the C•CURE 9000 Software Configuration Guide for information about events.
32 Chapter 3 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224611
VideoEdge Camera Alarms Tab
Table 6: VideoEdge 4.0 Camera Alarm Tab Definitions (continued)
Field Description
Camera tab (available if Video Camera Action was selected in the Action field)
Server Specify the server for the action. Click Q to open a list of predefined video servers.
NOTE: You must select the server before you can select the camera.
Camera Specify the camera for the action. Click Ei to open a list of predefined video cameras.
Action Type tab (available if Video Camera Action was selected)
Action Type Select the action type.
NOTE: Only Camera Preset Command and Camera Pattern Command are available.
Enter the parameters for the action type. The parameters vary according to the action type selected. See
Parameterson Page 33
Parameters
Pre Alarm Time Set the pre-alarm recording time for the camera when you select Record Camera as the action type.
Post Alarm Time Set the post-alarm recording time for the camera when you select Record Camera as the action type.
Preset Select the preset number as the object when you select Camera Preset Command as the action type.
Pattern Select the pattern number as the object when you select Camera Pattern Command as the action type.
VideoEdge Camera Alarm Configuration Example
Table 7 on Page 33 contains an example of how an Alarm is configured.
Table 7: Alarm Configuration Example
The following Alarms tab settings:
Property Value Action Details Schedule
Videoloss True Activate Display_l Always
Event
C•CURE 9000 VideoEdge Configuration Guide Chapter 3 33
EFTA01224612
VdeoEdge Camera Alarms Tab
Alarm Configuration Example (continued)
The following Alarms tab settings:
Would create the following Event
Anytime (Always Schedule) the Videoloss (Property) equals True (Value),
activate the event(Action) named Display_1 (Details).
Display_1 is an event you select in the Action Type pane.
For information about how to create and configure an event, see the
C•CURE 9000 Software Configuration Guide.
Configuring a Video Camera Alarm
To Configure a Video Camera Alarm
1. From the VideoEdge 4.0 Camera Editor, click on the Alarms tab.
2. Click Add.
3. Click in the Property column, and then click C.
4. Select the Property you want to be evaluated to trigger the alarm.
5. Click in the Value column and select from the following Values available according to the
Property selection.
• A check box:
- Select the Value check box if you want the Alarm triggered when the Property changes to
True.
- Leave the Value check box blank if you want the Alarm triggered when the Property
changes to False.
• Normal, Motion, Analytic, and Alarm
6. Select the Action that you want performed when the Alarm occurs. The bottom section of the
VideoEdge Camera Editor changes to reflect the choice:
• Activate Event
34 Chapter 3 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224613
VideoEdge Camera Alarms Tab
• Video Camera Action
7. If you chose Activate Event, click 0 in the Event field and choose an Event that you want
activated by the video Mann.
8. If you chose Video Camera Action:
• Click 0 in the Server field and choose the VideoEdge Server.
• Click 0 in the Camera field and choose the VideoEdge Camera you want activated.
9. Click the Action Type tab in the bottom section of the editor and choose the Action Type you
want the camera to perform. (The Action Types available for cameras may differ depending upon
the camera type.)
10. Choose the settings for the Action Type you specified.
11. Click Save and Close to save the configuration and exit.
Removing A Video Alarm
To Remove a Video Alarm
1. From the VideoEdge Camera dialog box, click on the Alarms tab.
2. Use • I to select the row in the Alarms table of the Mann you want to remove.
3. Click Remove.
4. Click Save and Close to save the configuration and exit.
C•CURE 9000 1ndeoEdge Configuration Guide Chapter 3 35
EFTA01224614
VideoEdge Camera State Images Tab
VideoEdge Camera State Images Tab
The State Images tab, shown in Figure 5 on Page 31, lets you change the default images used to
indicate the VideoEdge Camera states on the Monitoring Station.
The images are described in Table 8 on Page 37.
Figure 6: VideoEdge 4.0 Camera State Images Tab
cs Vidoxidge4.0 Omen - ammo 1-° - I C I l
it Save and Close je Save and Neat
name Caret-as
Netnobeo
Merit:14d
Genteel i Piss j an WOKS
State
Fccedn;
Ar
Connote
36 Chapter 3 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224615
VideoEdge Camera State Images Tab
Table 8: VideoEdge Camera State Images Icons
Icon State Description
Unknown The camera is in an unknown state
Recording The camera is recording.
V il Alarm The camera is in an alarm state.
Commloss There is no communication between the camera and the
0 video server.
Changing the VideoEdge Camera State Image
From the VideoEdge Camera State Images tab, you can change the images that appear in the
Monitoring Station to represent the VideoEdge Camera.
To Change a VideoEdge Camera State Image
1. In the VideoEdge Camera State Images tab, double-click on the existing image. A Wmdows
Open dialog box appears allowing you to browse for the folder in which you have placed
replacement images.
2. When you locate the replacement image, select it and click Open to replace the default image
with the new image.
3. Click Save and Close to save the camera configuration.
Restoring the VideoEdge Camera State Image to the Default Image
To Restore the VideoEdge Camera State Image to the Default Image
1. In the State Images tab, right-click on the image and select Restore Default.
C•CURE 9000 VldeoEdge Configuration Guide Chapter 3 37
EFTA01224616
VideoEdge Camera State Images Tab
2. Click Save and Close to save the camera configuration.
38 Chapter 3 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224617
VideoEdge Camera Viewer
VideoEdge Camera Viewer
The VideoEdge Camera viewer allows you to view video from all cameras connected to the
VideoEdge Server in the Administration Workstation.
The video server name and camera name displayed on top of the video stream comes
NOTE from the VideoEdge Server, not the names configured on C•CURE 9000.
There are three views that can be accessed by right-clicking on the video camera:
• View displays the video in a Dynamic View.
• Popup View displays the video in a pop-up Window.
• View in Current Tab displays the video in the current tab in the content area.
The VideoEdge Camera Viewer buttons are described in Table 9 on Page 39.
Table 9: Camera Viewer Button Descriptions
Button Description
la Displays camera information on the top of the video stream and playback controls on the bottom of the video
stream.
IP Takes a snapshot. This function is not avaiable.
15 Retrieves a recorded video.
Opens a Recorded Video Configuration so that you can select a certain period of time to retrieve a video. Sec
Retrieving a Recorded Video on Page 40
V Starts the video recording.
im
a. Reconnects the camera.
OP Exports video. See Exporting a Video on Page 41
C•CURE 9000 VideoEdge Configuration Guide Chapter 3 39
EFTA01224618
VdeoEdge Camera Viewer
Retrieving a Recorded Video
To Retrieve a Recorded Video
1. Click U to open a Recorded dialog box at the bottom of the window.
2. Click Time Range. The Retrieve Recorded Video dialog box, shown in Figure 7 on Page 40,
opens to enter the dates and times to retrieve the recorded video.
Figure 7: Retrieve Recorded Video
:3 Retrieve Recorded Vid
Start Date: IF/20/2010 • Start Time: 3:02:19 PM Get Video
End Date: 10/20/2010 End Time: 3:02:39 PM
If the Video Server is in a different time zone than the C•CURE 9000 client, you need
NOTE to calculate the time difference and enter the times and dates according to C•CURE
9000 client time.
Example:
If the C•CURE 9000 client is in Eastern Time (US & Canada) - UTC-5:00 and the
Video Server is in Pacific Time (US Sr Canada) - UTC - 8:00 to retrieve recorded video
for the time period 7:00 AM - 8:00 AM (Pacific Time) enter 10:00 AM-11:00 AM (the
equivalent in Eastern Time) in the search criteria.
3. Click Get Video to retrieve the recorded video for the dates and times specified. You are returned
to the VideoEdge Camera viewer and the video starts playing immediately, as shown in Figure 8
on Page 41.
■ The Retrieve recorded video button turns red when you are retrieving recorded video.
■ Click on to launch live video.
40 Chapter 3 C•CURE 9000 ladooEdge Configuration Guide
EFTA01224619
VideoEdge Camera Viewer
Figure 8: Playback Recorded Video
Exporting a Video
Video clips are exported in Native format ISO, which includes MP4 files. You can open MP4 film to
play recorded videos.
To Export a Video
1. Click III to export a pre-recorded video. The Retrieve Recorded Video dialog box, shown in
Figure 9 on Page 42, opens to enter the dates and times to retrieve the recorded video that you
want to export.
C•CURE 9000 indooEdge Configuration Guide Chapter 3 41
EFTA01224620
VideoEdge Camera Viewer
Figure 9: Retrieve Recorded Video
Start Date: 0:00/2010 Start Time: 3:02:19 PM Et:i Get Video
End Date: 10/20/2010 End Time: 3:02:39 PM Et:i /
2 Click Get Video to open the Save as dialog box. Select a folder to save the exported file in a
drop-down list and enter a filename.
3. Click Save. When save is complete, a dialog box opens informing of the export completion.
42 Chapter 3 C•CURE 9000 VldeoEdge Configuration Guide
EFTA01224621
VdeoEdge Playback Controls
VideoEdge Playback Controls
Playback Control provides all of the standard VCR operations (Fast Rewind, Play reverse, Play,
Pause, Play Forward, Fast Forward) as well as Jump Forward and Jump Back by intervals, giving
users total control over a video stream.
■ Playback controls is available only after selected one or more cameras from
NOTE viewer.
■ Audio is disabled when in instant playback unless you are running at x1 speed
forwards. Only one source can be running at any time. For example, enabling
audio on camera 2 will disable it on camera 1.
■ To enable audio when playing back retrieved video, select on the top right of
viewer. The icon turns green. Unless this is selected, the volume slider and mute
controls are disabled.
Instant Playback Controls
Instant Playback controls are shown in Figure 10 on Page 43. These are the controls available when
displaying live video.
Figure 10: Instant Playbadc Controls
lump in Reverse Play in WOW Ftt Toggle Flay/Pause
Toggle Audio /Mute lump Forward
Volume Control
Slider Select Date
edt Instant Playback
Playln Reverse Play Round NN44ayFoniani Fast
Table 10 on Page 44 describes the Instant Playback controls shown in Figure 10 on Page 43.
C•CURE 9000 bldeoEdge Configuration Guide Chapter 3 43
EFTA01224622
VideoEdge Playback Controls
Table 10: Instant Playback Controls Descriptions
Playback Control Description
Volume Control side, Used to control volume.
Toggle Audio/Mute Use to enable/disable audio on the current video stream.
Exit Instant Playback Use to exit playback and return to irve view.
Jump in Reverse Use to jump back by defined intervals- 30 seconds, 1minute, 5 minutes, 10 minutes, 30 minutes, 60
minutes
Play in Reverse Fast Use to Play video in reverse at various speeds. Available speeds are 2x. 3x. 4x.
Play in Reverse Use to play video lx in reverse.
Toggle Play/Pause Use to Pause/Play video.
Play Forward Use to play video lx.
Play Forward Fast Use to play video fotward at various speeds. Available speeds are 2x, 3x,4x.
Jump Forward Use to jump forward by defined intervals- 30 seconds, 1minute, 5 minutes, 10 minutes, 30 minutes,
60 minutes
Select Date via Use to select a date.
Calendar
44 Chapter 3 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224623
VideoEdge Playback Controls
Playback Controls Available While Viewing Recorded Video
Playback controls are shown in Figure 11 on Page 45. These controls are available while displaying
recorded video.
Figure 11: Playback Controls (Retrieve)
Jump In Reverse Play in Reverse Fast Toggle Play/Pause
Toggle Audio /Mute Jump Forward
Volume Control
heard Is
Slider
Play in Reverse Play Forward Flay Forward Fast
Table 11 on Page 45 describes the Playback controls shown in Figure 11 on Page 45.
Table 11: Playback ControlsAvaMble While Viewing Recorded Video Descriptions
Playback Control Description
Volume Controlslider Use to control volume level.
Toggle Audio/Mute Use to enable/disable audio on current video stream.
Jump in Reverse Use to jump back by defined intervals- 30 seconds, 1minute, 5 minutes, 10 minutes, 30 minutes,
60 minutes.
Play in Reverse Fast Use to Play video in reverse at various speeds. Available speeds are lx.2x. 3x, 4x.
Play in Reverse Use to Play video lx in reverse.
Toggle Play/Pause Use to Pause/Play video.
Play Forward Use to play video lx.
Play Forward Fast Use to play video forward at various speeds. Available speeds are 2* 3x, 4x.
C•CURE 9000 VideoEdge Configuration Guide Chapter 3 45
EFTA01224624
VideoEdge Playback Controls
Playback Controls Available While Viewing Recorded Video Descriptions (continued)
Playback Control Description
lump Forward Use to jump forward by defined intervals- 30 seconds, 1minutes, 5 minutes, 10 minutes, 30
minutes. 60 minutes
Options available in paused mode:
Step back multiple Use to jump back a set number of fra mes (depending on the frame rate the camera is set to).
frames
Step backone frame Step backone frame.
Step forward one frame Step forward one frame.
Step fonvard multiple Use to jump fonvard a set number of frames (depending on the frame rate the camera is set to).
frames
46 Chapter 3 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224625
4
Video View
This chapter describes how to create and configure a Video View.
In this chapter
Video View Editor 48
C•CURE 9000 VideoEdge Configuration Guide Chapter < 47
EFTA01224626
VideoView Editor
Video View Editor
The Video View Editor, shown in Figure 12 on Page 48, C•CURE 9000 lets you create Video View
objects without first creating a Video Tour. A Video View is a view from a camera or group of
cameras. It serves as a building block to construct a video tour. The Video View Editor fields and
buttons are described in Table 12 on Page 49
Video Edge Video Views are not supported on Windows 2008.
NOTE
Figure 12: VideoView
48 Chapter 4 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224627
Video View Editor
Table 12: Video View Editor Fields and Buttons Definitions
Field Description
Name Enter a unique name, up to 100 characters, to identify the Video View.
Description Enter a description , up to 500 characters, to identify the Video View.
Server Name Lists all the video hardware in the tree starting with the video server and the cameras connected to
Name it in rows. This is the default view
• To view the name of the server and al the cameras assigned to that server in a tree view. drag
Server Name to the Drag columns to group by here area, as shown in Figure 12 on
Page 48.
• To view all the cameras by name, drag Name to the Drag columns to group by here area.
The cameras are listed in row format. You can dick on the a next to a camera to view the
server name that the camera is connected to.
• re al El II 0 Enables you to select the number of cameras displayed inside the view. After you select a view grid
--' type, the appropriate view grid appears in the view area. Each grid is linked to a camera and
shows the video for that camera. Without a link to the camera, the grid remains blank. You can
choose 1x1, 2x2, 3x3, 4x4, 1x5 and 2x8 grid types.
NOTE: If you create a 1x5 a 2x8 view, which only has VideoEdge 4.X Cameras, there may have
several seconds latency when open the view.
See the C•CURE 9000 Da a Views Guide for descriptions of the Dynamic View buttons. Hovering the mouse cursor over the
button gives you a brief description.
Accessing the Video View Editor
To Access the Video View Editor in the Video Tree
1. In the Navigation pane of the C•CURE 9000 Administration Station, click Video to open the
Video Pane.
2. Expand the Video tree. Open the Company Name folder by clicking ► I to the left of the folder.
3. Open the Views folder by clicking ► I to the left of the folder.
4. In the Views folder, right-click the Video View that you want to access. Select Edit from the
context menu to open the Video View Editor.
C•CURE 9000 1fideoEdge Configuration Guide Chapter< 49
EFTA01224628
Video View Editor
To Access the Video View Editor in the Dynamic View
1. In the Navigation pane of the Administration Station, click Video to open the Video pane.
2. Select Video View from the Video pane drop-down list.
3. Click to open a Dynamic View showing all Video View objects.
4. Click on the Video View in the list to select it.
5. Right-click on the Video View and select Edit from the context menu. The Video View Editor
opens.
Creating a Video View
To Create a Video View
1. n the Navigation pane of the Administration Workstation, click Video to open the Video pane.
2. Open the video folder by clicking ► I to the left of the folder.
3. Right-click the Views and select New.
The Video View Editor opens, allowing you create a new view. For more information about
configuration, see Creating a Video View on Page 50.
4. Click Save and Close to save the configuration and exit.
Alternatively, if you want to save the video view and then create a new one, click Save and
Close. The current video view is saved and closed, but the Video View Editor remains open to
allow you create a new video view.
Configuring a Video View
To Configure a Video View
1. Create a new View or open an existing View. See Accessing the Video View Editor on Page 49
and Creating a Video View on Page 50.
2. Enter a unique name, up to 100 characters, in the Name field.
3. Enter a description (optional), up to 500 characters, in the Description field.
50 Chapter< C•CURE 9000 videoEdge Configuration Guide
EFTA01224629
Video View Editor
4. Click on the type of grid that you want to use for the Video View.
5. Expand the server folder and select the VideoEdge Camera that you want to add to the Video
View using drag and drop into the area below the grid icons.
It is recommended to add only VideoEdge cameras in one view in consideration
NOTE of performance.
When you add a VideoEdge Camera into the view, the view displays only the
VideoEdge Server name and the VideoEdge camera name, there is no video in
the camera preview window.
6. Click Save and Close to save the configuration and exit.
Deleting a Camera from the View
To Delete a Camera from the View
1. After you successfully add a camera, the camera name and an X appear on the top of the
image.
2. Click X to delete the camera from the view.
3. Click Save and Close to save and exit.
Deleting a Video View
To Delete a Video View on the Video Tree
1. In the Navigation pane of the Administration Workstation, click Video to open the Video pane.
2. Open the video folder by clicking Ito the left of the folder.
3. In the Video Tree, right-click on the Video View that you want to delete, and select Delete from
the context menu.
A message box appears stating "Are you sure that you want to delete the selected Video View
object?"
4. Click Yes to delete the view.
C•CURE 9000 VideoEdge Configuration Guide Chapter< 51
EFTA01224630
VideoView Editor
To Delete a Video View in the Dynamic View
1. In the Navigation pane of the Administration Workstation, click Video to open the Video pane.
2. Select Video View from the Video drop-down list.
3. Click Ell to open a Dynamic View displaying all the Video View objects.
4. Right-click on the View that you want to delete, and select Delete from the context menu.
A message box appears stating "Are you sure that you want to delete the selected Video View
object?"
5. Click Yes to delete the view.
52 Chapter < C•CURE 9000 IndeoEdge Configuration Guide
EFTA01224631
5
Video Tour
This chapter describes how to create and configure a Video Tour.
In this chapter
Video Tour Overview 54
VideoEdge Video Tour General Tab 57
C•CURE 9000 VldeoEdge Configuration Guide Chapters 53
EFTA01224632
Video Tour Overview
Video Tour Overview
A video tour is a list of views in sequence for a user-defined dwell time in a Live Video Window.
Video Tour Editor, as shown in Figure 13 on Page 54 lets you add or remove a video view on a
video tour, and adjust the sequence of video views.
This feature enables you to view live video from a configured collection of views that are configured
to display different cameras and camera groups in a time sequence.
Beginning with the first camera, video is displayed for a fixed amount of time before automatically
advancing to the next camera. This process continues until the last camera in the tour is reached, or
indefinitely if looping is enabled. Looping is the ability for a user to continuously replay the video
tour. In addition, users retain full access to PTZ Camera Control.
Figure 13: VideoTour Dialog Box
Qiu V.:Ito Tour Tour for Mdscept0
is S vic and Clo:c M Sat end Neu
54 Chapter 5 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224633
Video Tour Overview
Accessing the Video Tour Editor
To Access the Video Tour Editor in the Video Tree
1. In the Navigation pane of the C• CURE 9000 Administration Station, click Video to open the
Video pane.
2. Expand the Video tree. Open the video folder by clicking r I to the left of the folder.
3. Open the Tours folder by clicking r I to the left of the folder.
4. In the Tour Tree, right-click on the Tour that you want to access, select Edit from the context
menu to open the Video Tour Editor. See Accessing the Video Tour Editor on Page 55
Creating a Video Tour
To Create a Video Tour
1. In the Navigation pane of the Administration Workstation, click Video to open the Video pane.
2. Right-click on the video folder and select Video Tours>New.
The Video Tour Editor opens. See Configuring a Video Tour on Page 55
3. Click Save and Close to save and exit.
Configuring a Video Tour
To Configure a Video Tour
1. Create a new tour or open an existing tour. See Configuring a Video Tour on Page 55 and
Configuring a Video Tour on Page 55
2. Enter a unique name, up to 100 characters, in the Name field.
3. Enter a textual description (optional), up to 500 characters, in the Description field.
4. Create a configuration in the General tab. See VideoEdge Video Tour General Tab on Page 57
5. Click Save and Close to save the configuration and exit.
C•CURE 9000 IfitisoEdge Configuration Guide Chapter 5 55
EFTA01224634
Video Tour Overview
Deleting a Video Tour
To Delete a Video Tour in the Video Tree
1. In the Navigation pane of the Administration Workstation, click Video to open the Video Pane.
2. Open the video folder by clicking t I to the left of the folder.
3. Open the Tours folder by clicking t I to the left of the folder.
4. Right-click on the Tour that you want to delete, select Delete from the context menu.
A message box appears stating "Are you sure that you want to delete the selected tour?".
5. Click Yes to delete the tour.
To Delete a Video Tour in Dynamic View
1. In the Navigation pane of the Administration Station, click Video to open the Video pane.
2. Select Video Tour from the Video pane drop-down list.
3. Click a to open a Dynamic View showing all Tour objects.
4. Click on the tour in the list to select it.
5. Right-click on the Tour and select Delete from the context menu.
A message box appears stating "Are you sure that you want to delete the selected Tour?".
6. Click Yes to delete the tour.
58 Chapter 5 C•CURE 9000 VldeoEdge Configuration Guide
EFTA01224635
VideoEdge Video Tour General Tab
VideoEdge Video Tour General Tab
The Video Tour General tab lets you configure the Video Tour properties.
VideoEdge Video Tour General Tab Definitions
Table 13 on Page 57 describes the fields on the Video Tour General tab.
Table 13: Video Tour General Tab Definitions
Field Description
Name Enter a unique name up to 100 characters long to identify the Video Tour.
Description Enter a description up to 500 characters to dentify the Video Tour.
Tour If you select Tour Looping. the Video Tour continuousty startsover again after the finalcamera isdisplayed. If
looping not checked. the tour r uns onty once.
Show text If you select Show Text Overlay. predefined text appears over video. This function isnot available.
overlay
Preview Enables you to preview the tour. A separate window is created and displays all the views of the tour one-by-one
in sequence.See Vdeo Tour Preview Window on Page 57.
Add Opens the Video Tours Editor to add a Video View to the tour.
Remove Removes a Video View from the tour.
Move Up In the View list. click the cell to the left of a View to select the View. Then click Move Up to move the selected
video view up in the view sequence.
Move In the View list. click the cell to the left of a View to select the View. Then click Move Down to move the selected
Down video view down in the view sequence.
Video Tour Preview Window
The Video Tour Preview window displays the views of the tour is one-by-one, as shown in Figure 14
on Page 58
C•CURE 9000 VideoEdge Configuration Guide Chapter 5 57
EFTA01224636
VideoEdge Video Tour General Tab
Figure 14: Preview Window
Table 14 on Page 58 describes the buttons on the Preview window.
Table 14: Buttons and Berson the Preview Window.
Buttons & Bars Description
— Progress bar. Shows the progress of the video view.
D Reverses the video.
C t Pause the video.
kit
Forward the video.
o Track control- Shows the We camera move sequence.
Jl li
58 Chapter 5 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224637
6
Journal Messages
This chapter describes the customized Journal messages available after the VideoEdge integration,
In this chapter
Journal Message Definitions 60
C•CURE 9000 lade*Edge Configuration Guide Chapter 6 59
EFTA01224638
Journal Message Definitions
Journal Message Definitions
Table 15 on Page 60 lists the Journal Messages that can be reported by the VideoEdge Integration to
the C•CURE 9000 database.
In Table 15 on Page 60, objects, such as a panel name, point name, or computer name are
represented by the "#" symbol. The actual value for the object property will replace the "#" in the
Journal.
Table 1S: Journal Message Definitions
Message Object State Message
Type Change
sy,tum SofhvareHouse CrossFire VideoEdge 4.0 Video Driver Service
AL! y ty started on computer (#).
SofhvareHouse CrossFire VideoEdge 4.0 Video Driver Service
stopped on computer (#).
Syz,tem SoftwareHouse CrossFire VideoEdge 4.0 Video Driver Service
L!!! . started faded on computer (#}.
SoftwareHouse CrossFire VideoEdge 4.0 Video Driver Service
stopped faded on computer (4).
60 Chapter 6 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224639
Journal Message Definitions
Table 15: Journal Message Definitions (continued)
Message Object State Message
Type Change
NetVideo VideoEdge4.0 Online Server online on Server (4).
Activity Server
Offline Server offline on Server (4).
Protection VideoEdge4.0 Server 1#}' protection status normal.
Status: None
Storage Status: VideoEdge4.0 Server Ittystorage status normal.
Normal
Unit Status: VideoEdge4.0 Server '0yrecorder state normal.
Normal
VideoEdge4.0 Dry Contact Camera dry contact alarm started on VideoEdge 4.0 Video
Video Camera Camera (4).
Normal Camera drycontact alarm ended on VideoEdge 4.0 Video
Camera (4).
Video loss Camera video loss alarm started on VideoEdge 4.0 Video
Camera { # }.
Normal Camera video loss alarm ended on VideoEdge 4.0 Video
Camera { # }.
Motion Camera motion alarm started on VideoEdge4.0 Video Camera
(4).
Normal Camera motion alarm ended on VideoEdge 4.0 Video Camera
(4).
Pattern Pattern cmd on VideoEdge 4.0 Video Camera (4).
Preset Preset cmd on VideoEdge 4.0 Video Camera (4).
C•CURE 9000 VideoEdge Configuration Guide Chapter 6 61
EFTA01224640
Journal Message Definitions
62 Chapter 6 C•CURE 9000 VideoEdge Configuration Guide
EFTA01224641