Good morning Mr.Epstein the new increase of air flow to the bed room unit moves air across the
bed from the cornice above the same wall you are looking to install a split system. The floor vents
by the windows have also increased I would like to re direct that increased flow to blow at the
bed right now the air flow blows straight up . The problem with installing a split system in the
electric closet between the elevator and bed room is getting the condenser hooked up ,if we go to
a water cooled unit the riser pipes we would have to connect to are in the rear of the 3rdfl in the
message room which go up to the cooling tower on the roof ,we also need a plumbing drain line
for condensate drip which would require to connect nearest plumbing drain ( bed room pantry)
.The electric closet by the elevator is an electric riser closet only it was designed to keep water
away from the electric service. To go to air cooled split like LSJ the condenser unit needs to be
located outside to the nearest location out doors this area would be is a small set back below the
roof on the 5th floor faceing Howard Lutnick roof we would need to find a route to the 3fl closet
from that outside space. Either way this installation would require core drilling between floors and
opening ceilings. When you return home see how you feel with the new increase of air in the bed
room because we can do a better job of redirecting the air flow from above and below over the
bed. Richard
Date: Tue, 18 Jun 2013 07:18:46 -0400
Subject:
Fro • il.com
To:
can we put in a split unit on the wall between the bed an elevtor, the air would blow directly on
the bed,
***********************************************************
The information contained in this communication is
confidential, may be attorney-client privileged, may
constitute inside information, and is intended only for
the use of the addressee. It is the property of
Jeffrey Epstein
Unauthorized use, disclosure or copying of this
communication or any part thereof is strictly prohibited
and may be unlawful. If you have received this
communication in error, please notify us immediately by
return e-mail or by e-mail to jeevacation@gmail.com, and
EFTA_R1_00446527
EFTA01967417
destroy this communication and all copies thereof,
including all attachments. copyright -all rights reserved
EFTA_R1_00448528
EFTA01967418