From: jeffrey E. <jeevacation@gmail.com>
Sent: Sunday, May 3, 2015 12:36 AM
To: Larry Visoski
Subject: Re:
since the exit lights wnt on and the temp sensor funny?*=A0 thoguths
On Sat, May 2, 2015 at 7:46 PM, Larry Visoski <manta.. > wrote:
Sorry mi=sed your call,.
Exit signs have G sensors and power interruption=circuit,. That are normally powered by aircraft DC voltage,.
And hav= 2 D cell batteries in case of total electrical failure in emergency =/div>
A power interruption would cause exit sign to ill=minate
Sent from my =Phone
On May 2, 2015, at 5:40 PM, jeffrey E. <jeevacation@gmail.com&g=; wrote:
does=anything automatically trip to exit signs. . ???
Q=A0 please note
The information contained in this communicati=n is
confidential, may be attorney-client privileged, may
constitute=inside information, and is intended only for
the use of the addressee. =t is the property of
JEE
Unauthorized use, disclosure or copying of =his
communication or any part thereof is strictly prohibited
and may=be unlawful. If you have received this
communication in error, please n=tify us immediately by
return e-mail or by e-mail to jeevacation@gmail.com <mailto:=eevacation@gmail.com> , and
=estroy this communication and all copies thereof,
including all attachm=nts. copyright -all rights reserved
EFTA_R1_01629629
EFTA02501742
=C24> please note
The information contained in this co=munication is
confidential, may be attorney-client privileged, may
c=nstitute inside information, and is intended only for
the use of the ad=ressee. It is the property of
JEE
Unauthorized use, disclosure or co=ying of this
communication or any part thereof is strictly prohibitedand may be unlawful. If you have received this
communication in error,=please notify us immediately by
return e-mail or by e-mail to jeevacation@gmail.comga, and
destroy this communication and all copies thereof,
including =11 attachments. copyright -all rights reserved
2
EFTA_R1_01629630
EFTA02501743