EFTA00609974Set 9
24p9,270w
operation. The valve is a
pneumatically operated device with an internal electrical solenoid. As in all pneumatically operated
valves in this system, upstream duct pressure is used as the operating ... actuator and a venturi body. See Figure al
An internal shut-off electrical solenoid, when energized, ports operating air from the upstream side
(bleed air manifold) of valve directly into ... terminated. With a
source of air in the bleed air manifold and shut-off solenoid de-energized, valve butterfly moves
toward the open position and airflow through venturi body starts
https://www.justice.gov/epstein/files/DataSet%209/EFTA00609974.pdf
EFTA01119971Set 9
11p3,688w
operation. The
valve is a pneumatically operated de-
vice with an internal electrical solenoid.
An internal shutoff electrical solenoid,
when energized, closes this valve, pre-
venting any air from entering ... airflow.
Figure 11-4. Dorsal Fin Ram-Air Inlet
Electrical shutoff solenoid energizing causes
AIR CONTROL COMPONENTS the valve to be pressurized to the fully closed
position. There are several ... ways to energize
Bleed-Air Manifold the solenoid and close the valve:
The bleed-air manifold is used as the source of
bleed air for the air-conditioning system. This
https://www.justice.gov/epstein/files/DataSet%209/EFTA01119971.pdf
EFTA01735529Set 10
11p3,734w
operation. The
valve is a pneumatically operated de-
vice with an internal electrical solenoid.
An internal shutoff electrical solenoid,
when energized, closes this valve, pre-
venting any air from entering ... airflow.
Figure 11-4. Dorsal Fin Ram-Air Inlet
Electrical shutoff solenoid energizing causes
AIR CONTROL COMPONENTS the valve to be pressurized to the fully closed
position. There are several ... ways to energize
Bled-Air Manifold the solenoid and close the valve:
The bleed-air manifold is used as the source of
bleed air for the air-conditioning system. This
https://www.justice.gov/epstein/files/DataSet%2010/EFTA01735529.pdf
EFTA01114993Set 9
2013-04-0157p13,147w
SC13175 Invoice Number:
Total USD: $460.00
Discrepancy: 14.26 CMP GIV 732049 ENG HANDLE ACU SOLENOID CK
Resolution:
Step: 14.26.1 Completed In progress removal of R/H horizontal stabilizer and elevator panels ... book . All work I.A.W. GIV
MAI 55-14-00.
Discrepancy: 14.27 CMP GIV 732057 SOLENOID, ENG APPR IDLE-OPS
Resolution:
Discrepancy: 14.28 CMP GIV 732011 GROUND IDLE, ENG-TEST/ADJUST ... Engine Deceleration Test / Adjustment
Resolution:
Discrepancy: 14.38 CMP GIV 732050 ENG HANDLE ACU SOLENOID CK
Resolution:
Discrepancy: 14.39 CMP GIV 732058 SOLENOID, ENG AI'PR IDLE-OPS
Resolution:
Discrepancy
https://www.justice.gov/epstein/files/DataSet%209/EFTA01114993.pdf
EFTA00609734Set 9
2013-04-0157p13,185w
SC13175 Invoice Number:
Total USD: $460.00
Discrepancy: 14.26 CMP GIV 732049 ENG HANDLE ACU SOLENOID CK
Resolution:
Step: 14.26.1 Completed In progress removal of R/H horizontal stabilizer and elevator panels ... book . All work I.A.W. GIV
MAI 55-14-00.
Discrepancy: 14.27 CMP GIV 732057 SOLENOID, ENG APPR IDLE-OPS
Resolution:
Discrepancy: 14.28 CMP GIV 732011 GROUND IDLE, ENG-TEST/ADJUST ... Engine Deceleration Test / Adjustment
Resolution:
Discrepancy: 14.38 CMP GIV 732050 ENG HANDLE ACU SOLENOID CK
Resolution:
Discrepancy: 14.39 CMP GIV 732058 SOLENOID, ENG AI'PR IDLE-OPS
Resolution:
Discrepancy
https://www.justice.gov/epstein/files/DataSet%209/EFTA00609734.pdf
EFTA01122646Set 9
78p28,263w
external power
switch. The switch is held in the ON position by a solenoid. A temporary loss
AC power will allow the switch to return to the centre OFF position ... Arms the discharge button, Closes the fuel valve at the tank and
the fuel solenoid valve on the fuel control unit, Closes the air load control
valve, After ... engine driven pumps fitted to engines No1 and No2. The
pump switches control solenoid operated blocking valves, with the switches
on, normal pump output is supplied to the system
https://www.justice.gov/epstein/files/DataSet%209/EFTA01122646.pdf
EFTA01092968Set 9
2013-04-2315p6,110w
Engine Deceleration Test / Adjustment
14.26 Open CMP GIV 732049 ENG HANDLE ACU SOLENOID CK
14.26.1 Completed In progress removal of R/H horizontal stabilizer and elevator panels
required ... book . All work I.A.W. GIV M/M 55.14.00.
14.27 Open CMP GIV 732057 SOLENOID, ENG APPR IDLE-OPS
14.28 Open CMP GIV 732011 GROUND IDLE, ENG-TEST/ADJUST
14.29 Open ... Engine Deceleration Test / Adjustment
14.38 Open CMP GIV 732050 ENG HANDLE ACU SOLENOID CK
14.39 Open CMP GIV 732058 SOLENOID, ENG APPR IDLE-OPS
14.40 Open CMP GIV 750006 AIRFLOW
https://www.justice.gov/epstein/files/DataSet%209/EFTA01092968.pdf
EFTA00866526Set 9
2015-01-141p243w
Attachments: img-114122156-0001.pdf
Jeffrey,.
I have flap solenoid arriving tomorrow FedEx,. I have just proved this will NOT repair the issue,. I removed the pressure line
and pressurized the system,. even ... though I cannot hear the Thump,. I did have pressure coming out of solenoid.
I have called Gulfstream PSI to set up a travel team to help ... possible,. so I have to bring in the experts.
since pressure is available thru solenoid,. the next valve is the Flap control valve,. which makes sense,. if this unit
https://www.justice.gov/epstein/files/DataSet%209/EFTA00866526.pdf